22<br />

5 Mounting and dismounting<br />

5.2.4 Commissioning<br />

1. Before putting the roller lever limit switch into operation,<br />

ensure that it is sealed:<br />

– Ensure that the screws (5) on the cover (2) are<br />

tightened with a tightening torque of 1.5 Nm.<br />

– Check that the screwed cable gland (6) is<br />

tightened with a tightening torque of 6.7 Nm.<br />

– Check that the dummy plug (25) is fastened<br />

tightly.<br />

2. Check the entire belt misalignment switch and its<br />

components for damage.<br />

Screw (5)<br />

Dummy plug (25)<br />

Cover (2)<br />

Screwed cable gland (6)<br />

Screw (5)<br />

Fig. 5-12: Mounting the roller lever limit switch on the system<br />

HER and REL Operating instructions<br />

!<br />

Danger!<br />

Damaged roller lever limit switches must always be replaced.<br />