5 Mounting and dismounting<br />
5.2.4 Commissioning<br />
1. Before putting the roller lever limit switch into operation,<br />
ensure that it is sealed:<br />
– Ensure that the screws (5) on the cover (2) are<br />
tightened with a tightening torque of 1.5 Nm.<br />
– Check that the screwed cable gland (6) is<br />
tightened with a tightening torque of 6.7 Nm.<br />
– Check that the dummy plug (25) is fastened<br />
tightly.<br />
2. Check the entire belt misalignment switch and its<br />
components for damage.<br />
Screw (5)<br />
Dummy plug (25)<br />
Cover (2)<br />
Screwed cable gland (6)<br />
Screw (5)<br />
Fig. 5-12: Mounting the roller lever limit switch on the system<br />
HER and REL Operating instructions<br />
!<br />
Danger!<br />
Damaged roller lever limit switches must always be replaced.<br />