8<br />
3 Description<br />
3 Description<br />
Roller lever limit switches of the type HER and REL are<br />
used to limit the paths of machine parts for example in<br />
loading, mixed, and transport systems for bulk materials.<br />
Systems can be switched off promptly by the roller lever<br />
limit switch to prevent operational malfunctions.<br />
For example, roller lever limit switches of type HER and<br />
REL can be mounted on the ends of transport systems.<br />
Devices on the transport trolleys actuate the roller lever<br />
limit switches when the end of the transport path has<br />
3<br />
2<br />
1<br />
Roller lever (3)<br />
Transport trolley<br />
Fig. 3-1: Roller lever limit switch of type HER - mounting example<br />
been reached. The system is switched off and the transport<br />
trolley stopped (see fig. 3-1).<br />
The roller lever (3) can be moved in two directions. Depending<br />
on the device, the switch points are at a deflection<br />
of 5° (1) and 35° (2). Both switch points can be used<br />
to switch off the system (see section 5.2.3: “Adjusting the<br />
switch points”, page 19).<br />
HER and REL Operating instructions<br />