5.3.3 Environmental Requirements<br />

5.3.3.1 NORMAL OPERATIONAL ENVIRONMENT<br />

Doc No. SALT<strong>1700AS0001</strong> Issue A<br />

<strong>TCS</strong> <strong>Spec</strong>ification<br />

The <strong>TCS</strong> shall meet all the requirements specified in this document when operated in the<br />

computer room and control room ambient condition defined in Table 4 below:<br />

Parameter Value Notes<br />

Minimum Temperature in SALT rooms<br />

below observing floor<br />

10ºC<br />

Maximum Temperature in SALT rooms 30ºC Excluding Mirror coating room, where<br />

below observing floor<br />

no active <strong>TCS</strong> equipment is located.<br />

Minimum Temperature in Telescope<br />

Chamber<br />

0ºC<br />

Maximum Temperature in Telescope<br />

Chamber<br />

20ºC<br />

Minimum Humidity 5%<br />

Maximum Humidity 97% Non-condensing<br />

Site altitude 1798m<br />

Table 4: <strong>TCS</strong> Normal Operating Environment<br />

5.3.3.2 SURVIVAL ENVIRONMENT<br />

The <strong>TCS</strong> shall survive when exposed to environment specified in Table 5 below (non-specified<br />

values as per 5.3.3.1).<br />

Parameter Value Notes<br />

Minimum Temperature 0ºC<br />

Maximum Temperature 40ºC<br />

Maximum Humidity 100% Occasional exposure to condensing<br />

conditions<br />

Table 5: SALT Survival Operating Environment<br />