Biotech, chemical, petrochemical & pharmaceutical - HiQ® Specialty ...
Biotech, chemical, petrochemical & pharmaceutical - HiQ® Specialty ...
Biotech, chemical, petrochemical & pharmaceutical - HiQ® Specialty ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
HiQ ® specialty gas program – <strong>Biotech</strong>, <strong>chemical</strong>, petro<strong>chemical</strong> & <strong>pharmaceutical</strong><br />
Services<br />
used both in the relevant country and across borders. All gas products<br />
are quality controlled. Where applicable, an analysis certificate<br />
is included in the product. If not included, it can be requested separately.<br />
Please check with your local Linde office to find out what<br />
is applicable for the products you order.<br />
Name Prod. code<br />
HiQ ® Analysis certificate (Certified standard) 2921<br />
Explanations on the HiQ ® Analysis Certificate<br />
1 The date when the certificate was written, the beginning of the<br />
shelf life<br />
2 Identification of the HiQ ® Certificate<br />
3 Type of HiQ ® certificate e.g., “Certificate of Analysis,”<br />
“Certificate of Conformity”, etc.<br />
4 HiQ ® product name and code when applicable<br />
5 Comments on the table<br />
– the unit can be given either in mole, volume or weight<br />
– the uncertainty refers to the analysis of each component<br />
and is relative<br />
– if an absolute uncertainty is given it is In the column<br />
“Analysis result” (for instance 202 ± 4 ppm)<br />
6 Confidence level is the probability of the analysis result falling<br />
between the uncertainty limits<br />
7 The blend tolerance of a gas mixture specifies how close to the<br />
ordered concentration the final concentration must fall<br />
8 Following the temperature recommendation improves safety<br />
and helps to keep the gas mixture homogeneous<br />
9 The component concentrations will remain within the limits<br />
stated in the analysis result down to the recommended minimum<br />
pressure of use<br />
10 Use before: In a correctly handled cylinder the component concentrations<br />
will remain within the limits stated in the analysis<br />
result during the stated shelf life<br />
Reference material<br />
Calibration certificate<br />
National borders no longer define today’s environment. Pollutions<br />
are monitored on regional and even global scale. This requires that<br />
the results from the monitoring systems shall not only be comparable,<br />
but also mutually acceptable. Governments use accreditation<br />
as an instrument in these regulatory issues. Also in trading of<br />
goods, a confident and trustful base is needed to qualify and quantify<br />
the value of the traded goods. Accreditation is widely accepted<br />
as a tool to address issues like competence and reliability.<br />
Calibration certificates are used as a base to facilitate easy trading.<br />
Reference material with a calibration certificate is analyzed at a laboratory<br />
that has accredited analysis methods for the components<br />
and ranges in question.<br />
Several Linde facilities have such accredited analysis methods, especially<br />
for components and ranges used for environmental surveillance.<br />
Linde laboratories are accredited as calibration laboratories.<br />
Further, several facilities are accredited as testing laboratories<br />
to facilitate analytical services.<br />
The reference materials prepared by these production facilities<br />
are acknowledged as standard reference material by e.g., CAI,<br />
COFRAC, DAR, ENAC, RVA, SWEDAC, UKAS and many others.<br />
These products are in accordance with ISO 17025. An accreditation<br />
proves that the laboratory is competent to perform a certain<br />
analysis. The competence of the laboratory is decisive for the accreditation,<br />
and to achieve an accreditation it is mandatory to have<br />
a quality system. Linde specialty gas plants are ISO 9000 certified.