HiQ ® specialty gas program – <strong>Biotech</strong>, <strong>chemical</strong>, petro<strong>chemical</strong> & <strong>pharmaceutical</strong><br />

Points of use<br />

L 40 – Laboratory cupboard design<br />

The point of use is especially developed for specialty gases with<br />

high demands of purity, tightness and safety. The point of use is intended<br />

for mounting with gas supply line hidden behind a wall.<br />

Design F is a version with fixed pressure and flow meter.<br />

Product Prod.<br />

name bar psi code<br />

L 40 A, brass n.a. n.a. 3275<br />

L 40 A, stainless steel n.a. n.a. 3276<br />

L 40 B, brass 0.1–1 1.5–15 3277<br />

L 40 B, brass 0.5–6 8–85 3279<br />

L 40 B, brass 1–10.5 15–150 3281<br />

L 40 B, stainless steel 0.1–1 1.5–15 3278<br />

L 40 B, stainless steel 0.5–6 8–85 3280<br />

L 40 B, stainless steel 1–10.5 15–150 3282<br />

L 40 C, brass 0.1–1 1.5–15 3283<br />

L 40 C, brass 0.5–6 8–85 3285<br />

L 40 C, brass 1–10.5 15–150 3287<br />

L 40 C, stainless steel 0.1–1 1.5–15 3284<br />

L 40 C, stainless steel 0.5–6 8–85 3286<br />

L 40 C, stainless steel 1–10.5 15–150 3288<br />

L 40 F, brass 3 45 5429<br />

L 40 F, stainless steel 3 45 5430<br />

Technical Data<br />

Max primary pressure 40 ; 550<br />

[bar ; psi]<br />

Secondary pressure 0.1–1 ; 1.5–15<br />

[bar ; psi] 0.5–6 ; 8–85<br />

1–10.5 ; 15–150<br />

Pressure gauge scale –1–1.5 ; –14.5–21<br />

[bar ; psi] –1–10 ; –14.5–145<br />

–1–18 ; –14.5–260<br />

Max flow (nitrogen) 2 ; 700<br />

[Nm 3 /h ; SCFH] 6 ; 2,100<br />

11 ; 3,850<br />

Material Brass, Ni/Cr plated<br />

Stainless steel 316L<br />

Operating temperature –20–+70°C ; –4–+158°F<br />

Design A<br />

Design B Design C