Refurbishment example<br />

The following presents a reference calculation<br />

between a system with high-pressure<br />

mercury vapour lamps and high-pressure<br />

sodium-vapour lamps as a sample application<br />

for the energy-efficient refurbishment<br />

measure of a road lighting system.<br />

Here the installation geometry is defined<br />

as follows:<br />

(Maximum) light point height h 8.00 m<br />

Light point distance a 35.00 m<br />

Width of the traffic lane b 6.50 m<br />

Number of traffic lanes 2<br />

Width of a traffic lane 3.25 m<br />

Light distribution overlap s -0.5 m<br />

Luminaire inclination δ 15.0 °<br />

Calculation results for viewer B1<br />

Following project planning data<br />

were taken as a basis:<br />

Old installation New installation<br />

Average luminance L m / cd/m² 0.56 0.63<br />

Total uniformity U o 0.36 0.53<br />

Longitudinal uniformity U l 0.46 0.6<br />

Threshold value increase TI / % 13.2 11.8<br />

Mean illuminance E m / lx 9.34 9.51<br />

Total uniformity U o 0.32 0.3<br />

Surrounding illuminance ratio 0.79 0.5<br />

Maintenance factor 0.8<br />

Lighting class ME5<br />

Maintenance value of the illuminance 0.50 cd/m²<br />

Total uniformity Uo 0.35<br />

Longitudinal uniformity Ul 0.4<br />

Threshold value increase TI 15 %<br />

Surrounding illuminance ratio SR 0.5<br />

Number of calculation points 12/6<br />

Standard road surface C2<br />

Average luminance coefficient 0.07 (cd/m²)/lx<br />

Lamp equipment of old installation: 2 x 125 W HME, overall luminous flux 12600 lm<br />

Lamp equipment of new installation: 1 x 70 W HST, overall luminous flux 6600 lm<br />

Conclusion<br />

The calculation results for the new installation<br />

are not only better, but are also relevant<br />

especially with regard to the anticipated<br />

energy savings. The system rating of a light<br />

point of the old installation is 274 W compared<br />

to the new installation with a system<br />

rating of only 83 W. This results in a 30.3%<br />

savings in energy costs with better photometric<br />

values.<br />