Electrical technology<br />

Planning aid<br />

Electrical and functional safety<br />

<strong>TRILUX</strong> luminaires correspond to the statutory<br />

requirements of the EU low-voltage<br />

guideline and the EU EMC directive and thus<br />

bear the CE label. They correspond to the<br />

regulations of EN 60598 and have the ENEC<br />

label from the VDE test and certification<br />

board primarily as standard version.<br />

In addition to electrical safety, we test all<br />

materials used in our laboratories with<br />

regard to stability and their resistance to<br />

Ignition of high-pressure lamps<br />

High-pressure lamps generally require a<br />

special ignitor, which generates an ignition<br />

voltage of approx. 5 kV, in addition to the current-limiting<br />

reactor. A built-in timer limits<br />

the ignition time to the lamp-specific time.<br />

After that, any attempts to start the lamp will<br />

be interrupted. Doing so ensures, on the one<br />

hand, a safe ignition of the lamp and, on the<br />

other hand, prevents continual attempts to<br />

ignite faulty lamps.<br />

The “inner resistance” increases noticeably<br />

due to the high internal temperature of highpressure<br />

lamps. If a lamp goes out, e.g. due<br />

to a short voltage drop, it must cool down for<br />

up to 15 minutes in order to be switched<br />

back on using the normal ignitor.<br />

All luminaires for high-pressure discharge<br />

lamps are equipped with interference<br />

ignitors with automatic cut-off (timer). The<br />

automatic cut-off prevents constant ignition<br />

attempts in case of a defective lamp. The<br />

time interval for ignition attempts is selected<br />

in such a way that after a brief power failure<br />

a reignition of intact high-pressure sodiumvapour<br />

lamps and metal halide lamps is<br />

ensured. If a stable lamp operation is not<br />

Blind current compensation<br />

Blind current of luminaires connected to<br />

public power grids has to be compensated.<br />

If so desired, <strong>TRILUX</strong> outdoor luminaires can<br />

352<br />

corrosion and ageing. Constant quality<br />

controls secure the high quality standard of<br />

our products. During the long service life<br />

of outdoor lighting installations, there is the<br />

possibility that luminaires could be damaged.<br />

<strong>TRILUX</strong> guarantees a reliable replacement<br />

part supply. For instance, high impactresistant<br />

luminaires made of PMMA are<br />

usually still available at least 10 years after<br />

a luminaire series is discontinued.<br />

L1<br />

N<br />

3.1 Change-over for the adjustment to 2 lamp ratings.<br />

ÜZ<br />

achieved during this time interval, the timer<br />

built into the ignitor cuts off the ignition<br />

process. New ignition attempts are only<br />

made after a voltage-free switching.<br />

A large part of the luminaire range for highpressure<br />

lamps is supplied with ballasts<br />

for two lamp ratings. These luminaires are<br />

be equipped with a parallel capacitor for<br />

each lamp circuit. These pre-equipped<br />

parallel capacitors are PCB-free.<br />

adjusted on-site to the low capacity or are<br />

set to the low lamp rating for products with<br />

change-over switches. This power setting<br />

does not serve as wattage reduction but as<br />

adjustment of the ballast to the optimal operating<br />

conditions of the implemented lamp.