Application data type LP 40:<br />
Type stroke s [mm] rated speed<br />
max. v [m/s] 1)<br />
impact mass<br />
min. - max. m<br />
[kg]<br />
LIFT Buffer LP 40 + LP 50 3.0<br />
LP 40 For elevators up to 2,0 m/s rated speed<br />
according to En 81-1/2<br />
impact energy<br />
E [knm]<br />
buffer force<br />
F [kn]<br />
weight with oil<br />
filling G [kg]<br />
Article-no<br />
LP 40 x 80 80 1,0 450 - 3000 4,34 75 14 240080<br />
LP 40 x 120 120 1,3 450 - 3000 6,88 75 16 240120<br />
LP 40 x 175 175 1,6 450 - 3000 10,2 75 19 240175<br />
LP 40 x 275 275 2,0 450 - 3000 16,0 75 24 240275<br />
Application data type LP 50:<br />
Type stroke s [mm] rated speed<br />
max. v [m/s] 1)<br />
impact mass<br />
min. - max. m<br />
[kg]<br />
Dimensions type LP 40:<br />
S L N A B C D E F G P<br />
80 305 225<br />
120 385 265<br />
175 495 320<br />
275 715 440<br />
All dimensions in mm.<br />
Modifications reserved!<br />
Ambient temperatures for the standard design: +5 °C up to +50 °C.<br />
Other temperatures on request.<br />
LP 50 For elevators up to 3,2 m/s rated speed<br />
according to En 81-1/2<br />
Application data type LP 50:<br />
All dimensions in mm.<br />
Modifications reserved!<br />
Ambient temperatures for the standard design: +5 °C up to +50 °C.<br />
Other temperatures on request.<br />
impact energy<br />
max. E<br />
E [knm]<br />
160 120 20 18 112 115 140 80<br />
S L N A B C D E F G P<br />
425 1065 640<br />
695 1665 970<br />
300 160 20 18 135 155 150 100<br />
buffer force<br />
F [kn]<br />
weight with oil<br />
filling G [kg]<br />
Article-no.<br />
LP 50 x 425 425 2,5 500 - 4500 37,4 115 47 250425<br />
LP 50 x 695 695 3,2 600 - 4500 61,1 115 68 25069<br />
3<br />
33