13.02.2013 Views

2600 Test-A Pack System

2600 Test-A Pack System

2600 Test-A Pack System

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Burst Sensitivity Levels <strong>Pack</strong>age Pressure Decrease<br />

(max to min) (in H2O)<br />

1 4<br />

2 8<br />

3 12<br />

4 16<br />

5 20<br />

6 24<br />

7 28<br />

8 32<br />

9 36<br />

Pressure Limits psi in H2O kPa cm H2O<br />

Burst Pressure (max): 50 1384 344 3515<br />

Burst Pressure (min): 0.3 5 2.1 13<br />

Creep Pressure (max) 50 1384 344 3515<br />

Creep Pressure (min): 1.0 5 3.0 13<br />

Timer Range: 1 to 999 seconds<br />

<strong>Test</strong> Resolution: Within ± .2% full scale<br />

Serial Data Port: Configured to Electronic Industries Association<br />

Specification RS-232 format w/DB-9 female<br />

connector<br />

Selectable Baud Rates: 300, 600, 1200, 2400, 4800, 9600<br />

Parallel Printer Port: Simplified Centronics format w/DB-25 female<br />

connector<br />

Dimensions<br />

Length: 15.0 inches (381 mm)<br />

Width: 11.5 inches (292 mm)<br />

Height: 6.25 inches (159 mm)<br />

Weight: 13 lb (5.89 kg)<br />

Carleton Technologies Inc. doing business as Cobham Life Support II