1. LABEL<br />

Five adhesive labels are supplied with your multimeter clamp.<br />

Choose the label in your language and, above all, do not<br />

forget to stick it on the back of the clamp.<br />

This label contains a reminder of the main functions of your<br />

clamp and the maximum values which should not be<br />

exceeded.<br />

2. PRESENTATION<br />

The <strong>F11N</strong> and <strong>F13N</strong> multimeter clamps have 4,000<br />

measurement points with automatic calibre selection.<br />

These correspond to the inspection and maintenance<br />

requirements on all types of low-voltage electrical equipment.<br />

Their perfect ergonomics mean that these instruments are<br />

very simple to use.<br />

They directly measure AC intensities, without opening the<br />

circuit, in total safety :<br />

■<br />

■<br />

The <strong>F11N</strong> only for sinusoidal voltages and currents.<br />

The <strong>F13N</strong> gives the RMS value for any distorted or<br />

sinusoidal current and voltage.<br />

Their common functions :<br />

- AC currents up to 700 A,<br />

- DC and AC voltages up to 600 V,<br />

- max value of current and voltage,<br />

- resistances up to 4 kW ,<br />

- continuity sound test,<br />

- diode test,<br />

- memory.<br />

The specific function of the <strong>F13N</strong> :<br />

- frequencies up to 4kHz.<br />

Designed for professionals, these clamps meet the strictest<br />

safety criteria and international standards, particularly:<br />

- IEC 1010-1 and IEC 1010-2-032.<br />