4. ELECTRICAL CHARACTERISTICS<br />

4.1 Reference conditions<br />

■ Temperature : + 18°C to + 28°C<br />

■ Relative humidity : 45 % to 75 % RH<br />

■ Battery voltage : 9 V ± 0,1 V<br />

■ Position of the conductor : centred in the clamp<br />

■ Absence of external AC magnetic field<br />

■ Absence of electrical field<br />

■ Measurement on sinusoidal signal from 45 Hz to 65 Hz<br />

4.2 AC measurement extent : from 45 Hz to 450 Hz<br />

4.3 AC current<br />

Permitted<br />

A AC Resolution Accuracy (1)<br />

brief overload<br />

400 A 100 mA ± 2.5 % R ± 5 ct<br />

1000 A peak<br />

700 A 1 A ± 2.5 % R ± 5 ct (2)<br />

(1) For the <strong>F13N</strong>, additional error with the crest factor<br />

Fc from1.5 to 2.5 : 5 % R - Fc from 2.5 to 5 : 8 % R<br />

(2) From 0 % to 90 % of the range<br />

■ Influence on frequency : < 2 % R from 45 Hz to 450 Hz.<br />

4.4 DC voltage<br />

V DC Resolution<br />

Accuracy<br />

Input<br />

Impedance<br />

Permitted<br />

brief overload<br />

400 V<br />

600 V<br />

100 mV<br />

1 V<br />

± 1 % R ± 3 ct<br />

± 1 % R ± 2 ct<br />

1 MW<br />

1000 V rms<br />

4.5 AC voltage<br />

V AC<br />

Resolution<br />

Accuracy (1)<br />

Input<br />

Impedance<br />

Permitted<br />

brief overload<br />

400 V 100 mV ± 1.5 % L ± 5 ct<br />

1 MW 1000 V rms<br />

600 V 1 V ± 1.5 % L ± 3 ct<br />

(1) For the <strong>F13N</strong>, additional error with the crest factor<br />

Fc from 1.5 to 3 : 3 % R - Fc from 3 to 5 : 8 % R<br />

■ Influence on frequency : < 1 % R from 45 Hz to 450 Hz.<br />