Chauffe-eau émaillé à gran<strong>de</strong> puissance à double registre<br />
Données techniques VH-WPS/E 800 et 1000 litres<br />
Emaillé<br />
01 Thermomètre 1/2"<br />
02 Son<strong>de</strong> 1/2"<br />
03 Ano<strong>de</strong> <strong>de</strong> magnésium 11/4"<br />
05 Eau chau<strong>de</strong> 11/2"<br />
06 Circulation 3/4"<br />
07 Eau froi<strong>de</strong> 11/2"<br />
08 Aller chaudière 11/4"<br />
09 Retour chaudière 11/4"<br />
10 Aller énergie alternative 11/4"<br />
11 Retour énergie alternative 11/4"<br />
15 Doigt <strong>de</strong> gant pour son<strong>de</strong> ø 14x1.5<br />
16 Doigt <strong>de</strong> gant pour son<strong>de</strong> ø 14x1.5<br />
17 Raccord haut 11/4"<br />
19 Flasque ø 290/220<br />
32 Pieds<br />
05<br />
08<br />
15<br />
06<br />
09<br />
10<br />
16<br />
11<br />
07<br />
17<br />
01<br />
03<br />
19<br />
02<br />
32<br />
Type Temp.<br />
Débit permanent Débit <strong>de</strong> pointe Coeffizient NL<br />
départ<br />
charge<br />
tEF = 10 °C tEF = 10 °C tEC = 45 °C tEF = 10 °C<br />
tEC = 45 °C<br />
tEC = 45 °C tEC = 60 °C tBo = 50 °C tBo = 60 °C tBo = 50 °C<br />
Surface Débit<br />
éch. charge<br />
° C l/h kW l/h kW l/10min l/10min - m² m³/h mCE<br />
50.0 187.0 7.6 --- --- 856.0 --- 1.2<br />
60.0 374.0 15.2 --- --- 888.0 --- 2.3<br />
VH-800 WPS/E 70.0 552.0 22.5 262.0 15.2 919.0 972.0 3.4 2.2 4 0,6<br />
bas 80.0 727.0 29.6 396.0 23.1 949.0 1004.0 4.5<br />
90.0 902.0 36.7 524.0 30.5 979.0 1036.0 5.6<br />
50.0 468.0 19.0 --- --- 904.0 --- 2.9<br />
60.0 936.0 38.1 --- --- 985.0 --- 5.8<br />
VH-800 WPS/E 70.0 1380.0 56.2 655.0 38.1 1061.0 1123.0 8.5 5.2 4 0,6<br />
haut 80.0 1819.0 74.0 991.0 57.6 1136.0 1202.0 11.2<br />
90.0 2255.0 91.8 1310.0 76.2 1211.0 1282.0 13.9<br />
50.0 323.0 13.2 --- --- 1085.0 --- 2.0<br />
60.0 647.0 26.3 --- --- 1141.0 --- 4.0<br />
VH-1000 WPS/E 70.0 954.0 38.8 453.0 26.3 1194.0 1263.0 5.9 3.6 4 0,6<br />
bas 80.0 1257.0 51.1 685.0 39.8 1246.0 1318.0 7.8<br />
90.0 1558.0 63.4 905.0 52.6 1297.0 1373.0 9.6<br />
50.0 493.0 20.1 --- --- 1115.0 --- --<br />
60.0 987.0 40.2 --- --- 1199.0 --- 6.1<br />
VH-1000 WPS/E 70.0 1455.0 59.2 691.0 40.2 1280.0 1354.0 9.0 6.0 4 0,6<br />
haut 80.0 1918.0 78.0 1045.0 60.8 1359.0 1438.0 11.8<br />
90.0 2378.0 96.8 1382.0 80.3 1438.0 1522.0 14.7<br />
tEF = Température entrée eau froi<strong>de</strong> tEC = Température sortie eau chau<strong>de</strong> tBo = Température boiler<br />
Perte <strong>de</strong><br />
charge<br />
6.43 45