Liste de prix - Vaillant
Liste de prix - Vaillant
Liste de prix - Vaillant
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Chauffe-eau en acier inox à gran<strong>de</strong> puissance à double registre<br />
Données techniques VH-WPS/C <strong>de</strong> 800 et 1000 litres<br />
acier inox V4A<br />
01 Thermomètre 1/2"<br />
02 Son<strong>de</strong> 1/2"<br />
05 Eau chau<strong>de</strong> 11/2"<br />
06 Circulation 3/4"<br />
07 Eau froi<strong>de</strong> 11/2"<br />
08 Aller chaudière 11/4"<br />
09 Retour chaudière 11/4"<br />
10 Aller énergie alternative 11/4"<br />
11 Retour énergie alternative 11/4"<br />
14 Manchon 11/4"<br />
15 Doigt <strong>de</strong> gant pour son<strong>de</strong> ø 14x1.5<br />
16 Doigt <strong>de</strong> gant pour son<strong>de</strong> ø 14x1.5<br />
17 Raccord haut 11/4"<br />
19 Flasque ø 290/220<br />
32 Pieds<br />
05<br />
08<br />
15<br />
06<br />
09<br />
10<br />
16<br />
11<br />
07<br />
17<br />
01<br />
14<br />
19<br />
02<br />
32<br />
Type Temp.<br />
Débit permanent<br />
Débit <strong>de</strong> pointe<br />
Coefficient NL Surface Débit Perte <strong>de</strong><br />
départ<br />
tEF = 10 °C<br />
charge<br />
tEF = 10 °C<br />
tEF = 10 °C tEC= 45 °C<br />
tEC = 45 °C<br />
éch. charge charge<br />
tEC = 45 °C tEC = 60 °C tBo = 50 °C tBo = 60 °C tBo = 50 °C<br />
° C l/h kW l/h kW l/10min l/10min - m² m³/h mCE<br />
50.0 234.0 9.5 --- --- 864.0 --- 1.4<br />
60.0 468.0 19.0 --- --- 904.0 --- 2.9<br />
VH-800 WPS/C 70.0 690.0 28.1 328.0 19.0 942.0 997.0 4.3 2.2 4 0,6<br />
bas 80.0 909.0 37.0 496.0 28.8 980.0 1037.0 5.6<br />
90.0 1127.0 45.9 655.0 38.1 1018.0 1077.0 7<br />
50.0 585.0 23.8 --- --- 924.0 --- 3.6<br />
60.0 1170.0 47.6 --- --- 1025.0 --- 7.2<br />
VH-800 WPS/C 70.0 1725.0 70.2 819.0 47.6 1120.0 1185.0 10.6 5.2 4 0,6<br />
haut 80.0 2273.0 92.5 1239.0 72.0 1214.0 1285.0 14<br />
90.0 2819.0 114.7 1638.0 95.2 1308.0 1384.0 17.4<br />
50.0 404.0 16.5 --- --- 1099.0 --- 2.5<br />
60.0 808.0 32.9 --- --- 1169.0 --- 5.0<br />
VH-1000 WPS/C 70.0 1192.0 48.5 566.0 32.9 1235.0 1307.0 7.4 3.6 4 0,6<br />
bas 80.0 1571.0 63.9 856.0 49.8 1300.0 1375.0 9.7<br />
90.0 1947.0 79.3 1132.0 65.8 1364.0 1444.0 12.0<br />
50.0 617.0 25.1 --- --- 1136.0 --- --<br />
60.0 1234.0 50.2 --- --- 1242.0 --- 7.6<br />
VH-1000 WPS/C 70.0 1819.0 74.0 864.0 50.2 1342.0 1421.0 11.2 6.0 4 0,6<br />
haut 80.0 2397.0 97.6 1306.0 76.0 1442.0 1526.0 14.8<br />
90.0 2972.0 121.0 1727.0 100.4 1540.0 1630.0 18.3<br />
tEF = Température entrée eau froi<strong>de</strong> tEC = Température sortie eau chau<strong>de</strong> tBo = Température boiler<br />
6.45 47