11.07.2015 Views

CE Source Four jr & CE Source Four jr Zoom - SXS Events

CE Source Four jr & CE Source Four jr Zoom - SXS Events

CE Source Four jr & CE Source Four jr Zoom - SXS Events

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

and Phone: courtesy Audio-Visual 0870 of 080 Services 2342AccessoriesPortable Appliance Test (PAT) GuidelinesWhat is PAT?The Portable Appliance Test is a set of tests that must be administeredto electrical equipment in the UK and some locations in Europe toensure safety.The tests are typically carried out using a small PAT device. The PATdevice connects to a power source and then attaches to the productvia an electrical outlet and test probes. The PAT provides a simple passor fail result, allowing rapid testing of large inventories.The following guidelines provide instructions for applying the PAT tothe <strong>CE</strong> <strong>Source</strong> <strong>Four</strong> <strong>jr</strong>/<strong>Zoom</strong>.Testing New Luminaires<strong>CE</strong> <strong>Source</strong> <strong>Four</strong> <strong>jr</strong>/<strong>Zoom</strong> luminaires now include a specific PAT pointwhere the test clip is attached, as shown in the figure below. The PATtest is comprised of two tests: the ground test and the insulation test.EnglishPattern holder, M-size7062A10106.25” (15.875cm) donut 7060A1037mail: www.sxsevents.co.ukenquiries@sxsevents.co.uk6.25" (15.875cm) top hat 7060A10186.25" (15.875cm) colour frame 7060A3043Drop-in iris assembly7062A101130" (76.2cm) safety cable, black 7060A102250º lens assembly 7062A220436º lens assembly 7062A220326º lens assembly 7062A2201<strong>Zoom</strong> lens set<strong>Zoom</strong> lens front assembly<strong>Zoom</strong> lens rear assembly7062K40017062A20057062A2006Ground TestThe ground test indicates the safety of the ground connection to theburner unit and reflector-housing parts. The connection could becomelive if the insulation failed. It is not necessary to test continuity toeither the lens tube or the yoke, as these are separated by metallicshields.www.sxsevents.co.ukPAT pointFigure 10<strong>CE</strong> <strong>Source</strong> <strong>Four</strong> <strong>jr</strong> & <strong>CE</strong> <strong>Source</strong> <strong>Four</strong> <strong>jr</strong> <strong>Zoom</strong> • 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!