12.07.2015 Views

Manuale GATE 2 DG Rev.02 ITA (testo nero) - SEA (UK)

Manuale GATE 2 DG Rev.02 ITA (testo nero) - SEA (UK)

Manuale GATE 2 DG Rev.02 ITA (testo nero) - SEA (UK)

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

®Sistemi Elettronicidi Apertura Porte e CancelliInternational registered trademark n. 804888English<strong>GATE</strong> 2 <strong>DG</strong>PROGRAMMER JOLLY PARAMETERS ADJUSTMENTThe JOLLY programmer allows to keep under control and to change all parameters of the control unit without need to use thebuttons of the control unit. Compared to the on-board display, the programmer allows to view the programming instructions inthe user's language and in a non-encrypted way. In addition to the JOLLY programmer, the user can work comfortably standingup without looking at the control unit.Parameters displayed only with the software revision 37.Screen 1Language: ITScreen 2MotorEncSp.Decel.O1Sp.Decel.C1Available languages: IT,EN,FR,ES [ Italian, English, Spanish, French][Mech/Hydra/Sliding gate/Reversible Sliding gate]Encoder [on/off][Off÷100 ] motor 1 slowdown space in opening adjustment[Off÷100 ] motor 1 slowdown space in closing adjusmtentThe arrowindicates that theparameter can bechanged with the +and - buttons.Screen 3Sp.Decel.O2 [Off÷100 ] motor 2 slowdown space in opening adjustmentSp.Decel.C2 [Off÷100 ] motor 2 slowdown space in closing adjustmentSoftStart[0÷100 ] adjusts the acceleration rampTorque op.M1 [10÷100]% (max. motors current )Screen 4Torque cl.M1Torque op.M2Torque.cl.M2Cycle[10÷100]% (max. Motors current)[10÷100]% (max. Motors current)[10÷100]% (max. Motors current)[Secur./auto/deadman/step1/step2/two buttons]Screen 5Double leaf / Single leafPause time [0÷240]s (pausing time in seconds, 0s halfautomatic logic)LearningTimes learning [On-Off]Cycles [0÷... ] (Number of executed cycles )Screen 6PedestrianOpen delayClose delayAnti Intrusion[30÷100]% (Pedestrian opening rate)[Off÷6s]% (Leaf delay in opening)[Off÷20s]% (Leaf delay in closing)[Off,Open,Close.,op.cl.] (Implies the presence of a N.C. contact onlimit switch which if released forces the motors in closing)Screen 7Preblink [Close, Off, 0÷5s] (Only before closing, OFF from 0 to 5s)Light Time [Cycle, Off, 0÷240s] (Only during cycle, OFF from 0 to 240s)Ph.test[1,2-1-2] (Only on Foto1, only on Foto2, on both)Max Cycles[100÷100000] (Number of cycles for maintenance)Screen 8FlashPhoto1Photo2Edge 1[Normal/Control/always/beep][Close/Open/stop/park/close imm./rel.pause][Close./Open/stop/park/close imm./rel.pause]In 8K2 mangages balanced edge with 8k2 resistance.36 67411385<strong>Rev.02</strong> - 09/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!