18.03.2014 Views

KM 90/45 R - Kärcher

KM 90/45 R - Kärcher

KM 90/45 R - Kärcher

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Note:<br />

the operating instructions<br />

Observe<br />

on batteries is permitted only<br />

Work<br />

instruction by trained personnel<br />

after<br />

Danger!<br />

Wear safety goggles and<br />

<br />

clothing<br />

protective<br />

Observe regulations for the<br />

<br />

of accidents as well<br />

prevention<br />

DIN VDE 0510, VDE 0105 T.1<br />

as<br />

Danger!<br />

of fire and explosion!<br />

Risk<br />

Smoking prohibited<br />

—<br />

No naked flames, glowing<br />

—<br />

or sparks in the vicinity of<br />

embers<br />

batteries<br />

Do not place any objects or tools<br />

—<br />

the battery because voltage is<br />

on<br />

present between the<br />

always<br />

Areas in which batteries are<br />

—<br />

must be well ventilated,<br />

charged<br />

highly explosive gas forms<br />

as<br />

of acid burns!<br />

Danger<br />

Rinse out or rinse off splashes of<br />

<br />

in the eye or on the skin with<br />

acid<br />

quantities of clean water<br />

copious<br />

Then consult a doctor<br />

<br />

immediately<br />

Wash contaminated clothing with<br />

<br />

water<br />

Old batteries with this symbol are<br />

—<br />

commodities and must<br />

reusable<br />

be returned for<br />

therefore<br />

Old batteries which are not<br />

—<br />

for recycling must be<br />

returned<br />

of as special waste,<br />

disposed<br />

observing all statutory<br />

thereby<br />

regulations<br />

Note:<br />

folowing points are to be<br />

The<br />

if lead-acid storage<br />

observed<br />

are to be used for the unit:<br />

batteries<br />

Lead-acid storage batteries must<br />

—<br />

contained in a battery bath<br />

be<br />

(accessory).<br />

The maximum battery<br />

—<br />

The unit cover must remain open<br />

—<br />

charging of lead-acid<br />

during<br />

batteries.<br />

storage<br />

The battery manufacturer’s<br />

—<br />

must be complied<br />

instructionsj<br />

when charging wet batteries.<br />

with<br />

battery charger<br />

On-Board<br />

notes<br />

safety<br />

The battery charger may only be<br />

—<br />

if it is already mounted in a<br />

used<br />

conforming to<br />

status<br />

The battery charger may be<br />

—<br />

only with the following<br />

operated<br />

fuse protection: Safety<br />

mains<br />

of at least 10 A gL or an<br />

fuse<br />

fuse of at least 10 A (B<br />

automatic<br />

The battery charger may only be<br />

—<br />

for charging perfectcondition<br />

used<br />

lead drive batteries.<br />

The battery charger may be used<br />

—<br />

for maintenance-free<br />

only<br />

of a rated voltage of<br />

batteries<br />

V and a rated capacity of<br />

24<br />

Ah.<br />

160-180<br />

of fire and explosion!<br />

Risk<br />

the wrong types of batteries are<br />

If<br />

to the battery charger<br />

connected<br />

can excessively gas, gas out or<br />

they<br />

Danger!<br />

damages the battery<br />

Dampness<br />

and can cause<br />

charger<br />

electrocution.<br />

The unit is to be protected from<br />

—<br />

conducting dusts (for<br />

electrically<br />

soot, metal filings, ..).<br />

example,<br />

It is not permitted to use the<br />

—<br />

charger outdoors, on<br />

battery<br />

routes or in potentially<br />

traffic<br />

Keep children away from the<br />

—<br />

It is forbidden to modify the<br />

—<br />

Repairs of the battery charger<br />

—<br />

be performed only by a<br />

may<br />

specialist.<br />

qualified<br />

order<br />

Manufacturer’s/Kärcher’s<br />

code.<br />

6.654-070(*)<br />

EXIDE/DETA<br />

V PzS 175 (5)<br />

24<br />

low-maintence<br />

175 Ah<br />

Capacity:<br />

6.654-130<br />

EXIDE/DETA<br />

V GiV 180 DTP<br />

24<br />

maintenance-free<br />

180 Ah<br />

Capacity:<br />

6.654-089<br />

EXIDE/DETA<br />

V GiV 160 DTP<br />

24<br />

maintenance-free<br />

160 Ah<br />

Capacity:<br />

Warning!<br />

identified with an (*) are<br />

Batteries<br />

batteries.<br />

low-maintenance<br />

only maintenance-free batteries<br />

Use<br />

replacing batteries in Package<br />

when<br />

units.<br />

Note:<br />

deep-discharge protection has<br />

The<br />

be reset by the Kärcher aftersales<br />

to<br />

service for the respective<br />

if other batteries than those<br />

battery<br />

are used.<br />

recommended<br />

battery<br />

Maximum<br />

dimensions<br />

following maximum battery<br />

The<br />

must be maintained:<br />

dimensions<br />

set (4 pieces)<br />

Battery<br />

520 mm<br />

Length:<br />

380 mm<br />

Width:<br />

2<strong>90</strong> mm<br />

Height:<br />

battery<br />

Single<br />

260 mm<br />

Length:<br />

1<strong>90</strong> mm<br />

Width:<br />

2<strong>90</strong> mm<br />

Height:<br />

battery<br />

Recommended<br />

chargers<br />

order<br />

Manufacturer’s/Kärcher’s<br />

code.<br />

6.654-072<br />

KÄRCHER<br />

242544-ob-wa-23<br />

LG<br />

low-maintenance batteries<br />

for<br />

24 V<br />

Voltage:<br />

6.654-078<br />

KÄRCHER<br />

242544-ob-wf-23<br />

LG<br />

maintenance-free batteries<br />

for<br />

24 V<br />

Voltage:<br />

Note:<br />

6.648-582 supply cable/adapter is<br />

A<br />

and battery chargers can<br />

Batteries<br />

purchased in specialist shops.<br />

be<br />

Operating instructions <strong>KM</strong> <strong>90</strong>/<strong>45</strong> R English<br />

Battery safety instructions<br />

Recommended batteries<br />

recycling<br />

Description<br />

explode.<br />

Voltage: 4 x 6 V<br />

Voltage: 4 x 6 V<br />

dimensions must be observed.<br />

Description<br />

Voltage: 4 x 6 V<br />

explosive locations.<br />

battery poles<br />

battery and the battery charger.<br />

battery charger in any way.<br />

during charging<br />

specifications.<br />

required for both battery chargers.<br />

or C characteristic)<br />

26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!