Note:<br />
the operating instructions<br />
Observe<br />
on batteries is permitted only<br />
Work<br />
instruction by trained personnel<br />
after<br />
Danger!<br />
Wear safety goggles and<br />
<br />
clothing<br />
protective<br />
Observe regulations for the<br />
<br />
of accidents as well<br />
prevention<br />
DIN VDE 0510, VDE 0105 T.1<br />
as<br />
Danger!<br />
of fire and explosion!<br />
Risk<br />
Smoking prohibited<br />
—<br />
No naked flames, glowing<br />
—<br />
or sparks in the vicinity of<br />
embers<br />
batteries<br />
Do not place any objects or tools<br />
—<br />
the battery because voltage is<br />
on<br />
present between the<br />
always<br />
Areas in which batteries are<br />
—<br />
must be well ventilated,<br />
charged<br />
highly explosive gas forms<br />
as<br />
of acid burns!<br />
Danger<br />
Rinse out or rinse off splashes of<br />
<br />
in the eye or on the skin with<br />
acid<br />
quantities of clean water<br />
copious<br />
Then consult a doctor<br />
<br />
immediately<br />
Wash contaminated clothing with<br />
<br />
water<br />
Old batteries with this symbol are<br />
—<br />
commodities and must<br />
reusable<br />
be returned for<br />
therefore<br />
Old batteries which are not<br />
—<br />
for recycling must be<br />
returned<br />
of as special waste,<br />
disposed<br />
observing all statutory<br />
thereby<br />
regulations<br />
Note:<br />
folowing points are to be<br />
The<br />
if lead-acid storage<br />
observed<br />
are to be used for the unit:<br />
batteries<br />
Lead-acid storage batteries must<br />
—<br />
contained in a battery bath<br />
be<br />
(accessory).<br />
The maximum battery<br />
—<br />
The unit cover must remain open<br />
—<br />
charging of lead-acid<br />
during<br />
batteries.<br />
storage<br />
The battery manufacturer’s<br />
—<br />
must be complied<br />
instructionsj<br />
when charging wet batteries.<br />
with<br />
battery charger<br />
On-Board<br />
notes<br />
safety<br />
The battery charger may only be<br />
—<br />
if it is already mounted in a<br />
used<br />
conforming to<br />
status<br />
The battery charger may be<br />
—<br />
only with the following<br />
operated<br />
fuse protection: Safety<br />
mains<br />
of at least 10 A gL or an<br />
fuse<br />
fuse of at least 10 A (B<br />
automatic<br />
The battery charger may only be<br />
—<br />
for charging perfectcondition<br />
used<br />
lead drive batteries.<br />
The battery charger may be used<br />
—<br />
for maintenance-free<br />
only<br />
of a rated voltage of<br />
batteries<br />
V and a rated capacity of<br />
24<br />
Ah.<br />
160-180<br />
of fire and explosion!<br />
Risk<br />
the wrong types of batteries are<br />
If<br />
to the battery charger<br />
connected<br />
can excessively gas, gas out or<br />
they<br />
Danger!<br />
damages the battery<br />
Dampness<br />
and can cause<br />
charger<br />
electrocution.<br />
The unit is to be protected from<br />
—<br />
conducting dusts (for<br />
electrically<br />
soot, metal filings, ..).<br />
example,<br />
It is not permitted to use the<br />
—<br />
charger outdoors, on<br />
battery<br />
routes or in potentially<br />
traffic<br />
Keep children away from the<br />
—<br />
It is forbidden to modify the<br />
—<br />
Repairs of the battery charger<br />
—<br />
be performed only by a<br />
may<br />
specialist.<br />
qualified<br />
order<br />
Manufacturer’s/Kärcher’s<br />
code.<br />
6.654-070(*)<br />
EXIDE/DETA<br />
V PzS 175 (5)<br />
24<br />
low-maintence<br />
175 Ah<br />
Capacity:<br />
6.654-130<br />
EXIDE/DETA<br />
V GiV 180 DTP<br />
24<br />
maintenance-free<br />
180 Ah<br />
Capacity:<br />
6.654-089<br />
EXIDE/DETA<br />
V GiV 160 DTP<br />
24<br />
maintenance-free<br />
160 Ah<br />
Capacity:<br />
Warning!<br />
identified with an (*) are<br />
Batteries<br />
batteries.<br />
low-maintenance<br />
only maintenance-free batteries<br />
Use<br />
replacing batteries in Package<br />
when<br />
units.<br />
Note:<br />
deep-discharge protection has<br />
The<br />
be reset by the Kärcher aftersales<br />
to<br />
service for the respective<br />
if other batteries than those<br />
battery<br />
are used.<br />
recommended<br />
battery<br />
Maximum<br />
dimensions<br />
following maximum battery<br />
The<br />
must be maintained:<br />
dimensions<br />
set (4 pieces)<br />
Battery<br />
520 mm<br />
Length:<br />
380 mm<br />
Width:<br />
2<strong>90</strong> mm<br />
Height:<br />
battery<br />
Single<br />
260 mm<br />
Length:<br />
1<strong>90</strong> mm<br />
Width:<br />
2<strong>90</strong> mm<br />
Height:<br />
battery<br />
Recommended<br />
chargers<br />
order<br />
Manufacturer’s/Kärcher’s<br />
code.<br />
6.654-072<br />
KÄRCHER<br />
242544-ob-wa-23<br />
LG<br />
low-maintenance batteries<br />
for<br />
24 V<br />
Voltage:<br />
6.654-078<br />
KÄRCHER<br />
242544-ob-wf-23<br />
LG<br />
maintenance-free batteries<br />
for<br />
24 V<br />
Voltage:<br />
Note:<br />
6.648-582 supply cable/adapter is<br />
A<br />
and battery chargers can<br />
Batteries<br />
purchased in specialist shops.<br />
be<br />
Operating instructions <strong>KM</strong> <strong>90</strong>/<strong>45</strong> R English<br />
Battery safety instructions<br />
Recommended batteries<br />
recycling<br />
Description<br />
explode.<br />
Voltage: 4 x 6 V<br />
Voltage: 4 x 6 V<br />
dimensions must be observed.<br />
Description<br />
Voltage: 4 x 6 V<br />
explosive locations.<br />
battery poles<br />
battery and the battery charger.<br />
battery charger in any way.<br />
during charging<br />
specifications.<br />
required for both battery chargers.<br />
or C characteristic)<br />