14.09.2020 Views

16. Anadolu Gastroenteroloji Günleri Bildiri Özetleri

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SS42 [Pref.Pre: Sözlü Sunum]

Evaluation of the effect of parenteral esomeprozole on analytical phase ınteraction and

diagnostic test results

Ataman Gönel

Department of Medicinal Chemistry, Harran University, Sanliurfa, Turkey

AIM: Although monoclonal antibodies used in immunoassay analyzes are specifically produced for

analytes, there is interaction potential between xenobiotics and reagent antibodies. Clinical

reflection of this interaction in the analytical phase is the reason of false high or false low test

results. In immunoassay method, affected detector antibodies in the reagent solution may cause

false test results that are not noticed through clinicians in health services. The aim of this study is

to investigate the interaction of parenteral esomeprozole.

METHOD: The study was performed using the chemiluminescence immmunassay method

(Siemnes, Centaur XP, Germany) with hormone control material (BioRad, lot: 40333). 1800 µL of

the control solution was taken to the godet and 200 µL of esomeprozole was added in intravenous

form and vortexed and incubated for 20 minutes at room temperature. TSH, FT4, FT3, Mass

CKMB, Troponin-I, CA15-3, CA19-9 CA125, CEA, PSA, Ferritin, B12, PTH, FSH, LH, Progesterone,

Estradiol samples were studied from the control sample. The study was rerun by adding 200 µL

distilled water. Percentage deviations from target value were calculated with bias.

RESULTS: Bias values due to esomeprozole were TSH 9.52%,FT4 46.03%,FT3 -12.01%,CK-MB

mass 2.05%,Troponin-I 0.74%,CA15-3 -1.28%,CA 19-9 0.13%,CA125% -6.42%,CEA 1.99%,PSA

-5.59%,Ferritin -3.77%,B12 -12.07%, PTH 1.53% FSH was affected by -0.68%, LH -

7.08%,Progesterone 3.75%,Estradiol-11.62%.

CONCLUSION: One of the disadvantages of the immunochemical methods is the interaction with

xenobiotics and encountering erroneous results.Esomeprozole caused significant interference in

TSH, FT4, FT3, B12 and estradiol tests. Esomeprozole interference should be evaluated especially

in cases where vitamin B12 deficiency due to antral gastritis is considered.

Keywords: esomeprozole, interaction, immunoassay test, erroneous result