Safer practice notice 01. Improving infusion device safety. National Patient Safety<br />

Agency. 2004;1<br />

Standardising and centralising infusion devices – a project to develop safety<br />

solutions <strong>for</strong> NHS trusts. Full evaluation report. National Patient Safety Agency,<br />

May 2004.<br />

Joint Commission on Accreditation of Healthcare Organizations. Infusion pumps:<br />

Preventing future adverse events. Sentinel Event Alert. 2000;15:<br />

http://www.jcaho.org/about+us/news+letters/sentinel+event+alert/sea_15.htm<br />

Amoore J, Mather J, Scott DHT, Craig K. Infusion devices: most do not measure<br />

the volume infused. Anaesthesia. 1998:53:1231-32.<br />

Lönnqvist PA, Löfqvist B. Design flaw can convert commercially available<br />

continuous syringe pumps to intermittent bolus injectors. Intensive Care Med.<br />

1997;23:998-1001.<br />

Weiss M, Hug MI, Neff T, Fischer J. Syringe size and flow rate affect drug<br />

delivery from syringe pumps. Can J Anesth. 2000;47(10):1031-1035.<br />

Boström U. Ny standard för infusionspumpar – med bristar läkare bör känna till.<br />

Läkartidn. 1999;96(11):1327-1328.<br />

Schwartz Md, Gorelick M. Safey Hazard with Intravenous Pumps. Am J Dis Child.<br />

1989;143:1390-1391.<br />

Williams C, Lefever J. Reducing the risk of user error with infusion pumps. Prof<br />

Nurse. 2000;15(6):382-384.<br />

Keselman A, Patel VL, Johnson Tr, Zhang J. Institutional decisionmaking to select<br />

patient care devices: identifying venues to promote patient safety. J Biomed<br />

In<strong>for</strong>m. 2003;36:31-44.<br />

Zhang J, Johnson TR, Patel VL, Paige DL, Kubose T. Using usability heuristics to<br />

evaluate patient safety of medical devices. J Biomed In<strong>for</strong>m. 2003;36:23-30.<br />

Anonym. General-Purpose Infusion Pumps. Health Devices. 1998;27(4-5):151-<br />

170.<br />

3.6 Forebyggelse af intravaskulære kateterrelaterede<br />

infektioner<br />

Centrale venøse katetre er blevet essentielle redskaber til behandling af kritisk og<br />

kronisk syge patienter, da katetrene giver mulighed <strong>for</strong> administration af væsker,<br />

medicin og ernæring samt udtagning af blodprøver og hæmodynamisk<br />

monitorering. Disse katetre er dog årsag til infektioner i blodbanen associeret med<br />

en betydelig morbiditet og mortalitet. Mange af disse infektioner kan i dag<br />

<strong>for</strong>ebygges.<br />

<strong>Specifikke</strong> <strong>patientsikkerhedsstandarder</strong> – udvalgte procedurer med <strong>for</strong>bedringspotentiale<br />