For the Fitter<br />

2. Special settings<br />

Charging model is not in list or certain parameters must be changed<br />

Changes to the individual parameters are adopted immediately after they are entered. If no button<br />

is pressed for 15 minutes after a change has been made (irrespective of which parameter has been<br />

changed), the display automatically returns to the default display (time and outside temperature<br />

are shown alternately).<br />

Operating principle<br />

The following points are important in understanding the operating principle of the ELFAMATIC<br />

µC 3000:<br />

• The temperature used to calculate the output signal is not the instantaneously measured outside<br />

temperature but an average value derived from the determined instantaneous values with a<br />

trend component.<br />

• During standard operation, the ELFAMATIC µC 3000 functions in autosynchronisation mode,<br />

i.e. the timing element is synchronised with the main release automatically while taking the<br />

current time into consideration. As a result, it is no longer necessary to set the number of hours<br />

since release start (operating time). When put into operation for the first time, the controller<br />

operates in forward control mode until it receives the first LF main release pulse; this ensures<br />

that charging is performed if an additional release is given during this time.<br />

• With charging models where a permanent release is given, e.g. at the weekend (Powertherm), the<br />

ELFAMATIC µC 3000 uses the previous release times to determine the start times for main release<br />

and additional release. If the ELFAMATIC µC 3000 is put into operation on a Friday (so that it is<br />

not possible to store the release times), synchronisation could take until Monday evening. During<br />

this time, the controller operates in forward control mode in order to ensure that charging is<br />

performed.<br />

Interaction of the adjusters<br />

with the ELFAMATIC µC 3000<br />

Factory settings:<br />

Charging model 1<br />

E1 = -<strong>14</strong> °C<br />

E2 = 18 °C<br />

LSO = 15 %<br />

E3 = 7 h<br />

TEP = 20 %<br />

TSP = 85 %<br />

100 %<br />

Charging<br />

level<br />

-20 -15 -10 -5 0 5 10 15 20 25<br />

Example of charging characteristic with 2 °C<br />

outside temperature<br />

100 %<br />

80 80<br />

60 60<br />

Nominal charging level<br />

(heat content)<br />

40 40<br />

20 20<br />

0<br />

E1<br />

Example with outside temperature<br />

LSO<br />

Start point is determined by the<br />

controller on the basis of the<br />

required charging level<br />

-20 -15 -10 -5 0 5 10 15 20 25 2 4 6 8 10 12 <strong>14</strong> 16 18 20 22 24<br />

Outside temperature (°C) Operating time (h)<br />

E2 E3<br />

TSP<br />

UZ<br />

(22 h)<br />

Nominal charging level =<br />

100 % TSP<br />

Full charging<br />

of storage<br />

heater<br />

TEP<br />

100 % TEP<br />

25<br />