13.07.2015 Aufrufe

Leseprobe aus: In die Stille gehen von Choa Kok Sui ... - PranaHaus

Leseprobe aus: In die Stille gehen von Choa Kok Sui ... - PranaHaus

Leseprobe aus: In die Stille gehen von Choa Kok Sui ... - PranaHaus

MEHR ANZEIGEN
WENIGER ANZEIGEN

Erfolgreiche ePaper selbst erstellen

Machen Sie aus Ihren PDF Publikationen ein blätterbares Flipbook mit unserer einzigartigen Google optimierten e-Paper Software.

Light MetersL.E.D. Radiometersds/Kerr(4.6)1REALITY’SCHOICESCost: $183.35NEWWarranty: 2 yearsDescriptionBlue plastic. It has a recessed 7mm porthole that has a series ofconcentric rings around it to help stabilize a curing tip. The ringsare also recessed on different levels. For example, the deepest ring(flush with the light-sensitive porthole) is 9.7mm in diameter.This ring would be used for 8mm tips. The next ring, slightly(1.0mm) elevated from the first one, is 12.7mm in diameter andwould be used for 11mm tips. The last ring, also slightly elevatedfrom the previous one, is 14.7mm in diameter and would be usedfor 13mm tips. It has an analog gauge, which reads in mW/cm 2from 0-2000 in 200mW/cm 2 increments. Its name and abbreviatedinstructions are printed on the back of the unit.DimensionsLengthWidthThickness4.75in/12.1cm3.0in/7.6cm1.1in/2.9cmMeasures all types of lightsUpper limit is 2,000 mW/cm 2Analog gauge not preciseNeed to read while light is activatedUseAll you do is place your light tip over its porthole and activate thelight. The curing light actually supplies the power. There is no batteryor on-off switch.DirectionsPlain paper sheets simply stapled, 16 languages. Gives good informationin a logical manner. However, the recommendation to usethe enclosed Hardness Disk to check whether composite is curedor not is probably not a good idea, since our tests show thismethod of checking curing effectiveness is not reliable.Optilux Radiometersds/Kerr(4.5)2REALITY’SCHOICESCost: $183.35Warranty: 1 yearDescriptionOff-white plastic. It has a recessed 7mm porthole that has a seriesof concentric rings around it to help stabilize a curing tip. Therings are also recessed on different levels. For example, the deepestring (flush with the light-sensitive porthole) is 9.7mm in diameter.This ring would be used for 8mm tips. The next ring, slightly(1.0mm) elevated from the first one, is 12.7mm in diameter andwould be used for 11mm tips. The last ring, also slightly elevatedfrom the previous one, is 14.7mm in diameter and would be usedfor 13mm tips. It has an analog gauge, which reads in mW/cm 2from 0-1000 in 100mW/cm 2 increments. Its name and abbreviatedinstructions are printed on the back of the unit.DimensionsLengthWidthThickness4.75in/12.1cm3.0in/7.6cm1.1in/2.9cmEasiest to use — not even a power switchNo resetting necessary after usingAnalog gauge not preciseNeed to read while light is activatedUseAll you do is place your light tip over its porthole and activate thelight. The curing light actually supplies the power. There is no batteryor on-off switch.DirectionsHandbook, six languages. Gives good information in a logicalmanner. However, the recommendation to use the enclosedHardness Disk to check whether composite is cured or not isprobably not a good idea, since our tests show this method ofchecking curing effectiveness is not reliable.©2005 REALITY Publishing Co. Vol. 19 The Ratings 711

Hurra! Ihre Datei wurde hochgeladen und ist bereit für die Veröffentlichung.

Erfolgreich gespeichert!

Leider ist etwas schief gelaufen!