8.11 Setting the offset values for the individual<br />

actuator "OFF"<br />

If multiple actuators on various heaters are controlled by the<br />

same controller, the heating of the individual heaters may be<br />

uneven. This may be because of a severe non-uniform valve<br />

flow between the valves and/or poorly dimensioned heaters. The<br />

effect may possibly be able to be rectified with more (positive<br />

offset) or less (negative offset) heating on individual heaters.<br />

Call up special function "OFF" to make the setting and confirm<br />

with the "OK" button.<br />

Use the setting dial to select the desired actuator and confirm<br />

with the "OK" button. Use the setting dial to set an offset value of<br />

0-25% for the selected actuator. Confirm the entry with the "OK"<br />

button.<br />

8.12 Setting the set ventilation temperature<br />

(Window open temperature) "WOT"<br />

You can set the temperature for the individual sensors, which<br />

should be attained when an open window is detected.<br />

Call up special function "WOT" and confirm with the "OK" button.<br />

The number of the sensor for which the window open temperature<br />

should be changed, the symbol for an open window and the<br />

defined window open temperature are shown on the display.<br />

Now choose the desired sensor using the setting dial. Confirm<br />

with the "OK" button and set the window open temperature for<br />

the selected sensor.<br />

55