Version ; 200228<br />

42<br />

Alarms<br />

1 Gyro alarm<br />

This indication will light up if the rate gyro is not working properly or has not reached the<br />

required speed (immediately after switching-on), to show that the indication is not reliable.<br />

This indicator will switch-off again as soon as the rate gyro has reached the required speed<br />

and/or is functioning properly.<br />

2 Rudder system alarm<br />

If the rudder system does not respond to the control commands of the pilot. The <strong>Sigma</strong><br />

<strong>550</strong> gives a rudder alarm.<br />

3 Course alarm.<br />

If in the turn-indicator function, the difference between the rate-of-turn set and the rateof-turn<br />

measured exceeds the alarm value set by more than 12 seconds, a course alarm will<br />

be sounded.<br />

4 Voltage alarm<br />

If there is no voltage or if the voltage is too low for the correct working of the pilot, a<br />

voltage alarm will be given. If all the voltages are ok and the <strong>Sigma</strong> <strong>550</strong> is switched-on, this<br />

indicator will light-up in green.<br />

In the case of a communication alarm, the voltage alarm will flash and the acoustic alarm<br />

cannot be reset.