Comfort 211 accu / solar - Marantec
Comfort 211 accu / solar - Marantec
Comfort 211 accu / solar - Marantec
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
6. Installation<br />
6.9 Connection of external control elements<br />
6.9 / 1<br />
i<br />
Attention!<br />
In order to avoid damages to the control unit:<br />
- only connect potential-free closing contacts to terminals 1 and 2 (A).<br />
- do not insert the short-circuit plug (C) into socket (D)!<br />
C B A D<br />
3 1 2 70 71<br />
1<br />
23<br />
7<br />
6 5 4<br />
8<br />
1 2<br />
A Connection of operating elements without system cabling on site only with connecting terminals:<br />
1 24 V DC max. 50 mA<br />
2 impulse<br />
3 GND<br />
70 GND<br />
70 + 71 Two-wire photocell<br />
B Socket for "external control elements"<br />
(No connection possible)<br />
C Short-circuit plug<br />
D Socket for system photocell or adapter cable for modular aerial.<br />
E Modular antenna connection<br />
S1 On-site impulse key (if available)<br />
Reference:<br />
To install external control elements, refer to the corresponding instructions.<br />
26 Manual for installation and operation, <strong>Comfort</strong> <strong>211</strong> <strong>accu</strong> / <strong>solar</strong> GB (#73385)<br />
E<br />
P<br />
S1<br />
3 1 2 70 71<br />
A