10. Messages<br />
10.3.2 Malfunctions with error message<br />
Error Cause Solution<br />
LED 6 flashes regularly. A malfunction has been registered.<br />
By quickly pressing the P button, one or more displays will subsequently flash irregularly.<br />
By summing the corresponding numbers, you can determine the error number.<br />
Message 6 - external photocell interrupted or<br />
defective.<br />
- Photocell is programmed but not<br />
connected.<br />
- remove obstacle or check photocell.<br />
- Deactivate photocell or connect it.<br />
Message 7 - after 120 seconds without pressing a button, the programming mode terminates automatically.<br />
Message 8 - defective reference point switch. - check operator.<br />
Message 9 - defective RPM sensor /<br />
blocked operator or operator booms.<br />
Message 10 - door movement too stiff.<br />
- blocked door.<br />
- Maximum driving power is set too<br />
low.<br />
- check operator and operator booms<br />
- make door easily moveable.<br />
- Have maximum drive power (section 9.3.3 / menu 1+2)<br />
checked by specialist dealer.<br />
Message 11 - excess travel stop - check operator and operator booms.<br />
Message 15 - External photocell defective. - Have photocell checked.<br />
Message 16 - defective power sensor for the<br />
automatic cut-out.<br />
Message 26 - undervoltage,<br />
operator overloaded by setting to<br />
max. power step 16.<br />
Message 28 - door movement too stiff or irregular.<br />
- blocked door.<br />
- check operator and operator booms.<br />
- check building power supply.<br />
- check door movement and make door easily moveable.<br />
- automatic cut-out set too sensitive. - Have automatic cut-out checked by specialist dealer<br />
(section 9.3.3 / menu 3).<br />
Message 35 - defective electronics. - check operator.<br />
Message 36 - short-circuit plug removed, although<br />
a stop button is not connected.<br />
- closed circuit interrupted.<br />
- Connect stop button or insert short-circuit plug (Section 6.9).<br />
Manual for installation and operation, <strong>Comfort</strong> <strong>211</strong> <strong>accu</strong> / <strong>solar</strong> GB (#73385) 49