03.03.2013 Views

Comfort 211 accu / solar - Marantec

Comfort 211 accu / solar - Marantec

Comfort 211 accu / solar - Marantec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10. Messages<br />

10.3.2 Malfunctions with error message<br />

Error Cause Solution<br />

LED 6 flashes regularly. A malfunction has been registered.<br />

By quickly pressing the P button, one or more displays will subsequently flash irregularly.<br />

By summing the corresponding numbers, you can determine the error number.<br />

Message 6 - external photocell interrupted or<br />

defective.<br />

- Photocell is programmed but not<br />

connected.<br />

- remove obstacle or check photocell.<br />

- Deactivate photocell or connect it.<br />

Message 7 - after 120 seconds without pressing a button, the programming mode terminates automatically.<br />

Message 8 - defective reference point switch. - check operator.<br />

Message 9 - defective RPM sensor /<br />

blocked operator or operator booms.<br />

Message 10 - door movement too stiff.<br />

- blocked door.<br />

- Maximum driving power is set too<br />

low.<br />

- check operator and operator booms<br />

- make door easily moveable.<br />

- Have maximum drive power (section 9.3.3 / menu 1+2)<br />

checked by specialist dealer.<br />

Message 11 - excess travel stop - check operator and operator booms.<br />

Message 15 - External photocell defective. - Have photocell checked.<br />

Message 16 - defective power sensor for the<br />

automatic cut-out.<br />

Message 26 - undervoltage,<br />

operator overloaded by setting to<br />

max. power step 16.<br />

Message 28 - door movement too stiff or irregular.<br />

- blocked door.<br />

- check operator and operator booms.<br />

- check building power supply.<br />

- check door movement and make door easily moveable.<br />

- automatic cut-out set too sensitive. - Have automatic cut-out checked by specialist dealer<br />

(section 9.3.3 / menu 3).<br />

Message 35 - defective electronics. - check operator.<br />

Message 36 - short-circuit plug removed, although<br />

a stop button is not connected.<br />

- closed circuit interrupted.<br />

- Connect stop button or insert short-circuit plug (Section 6.9).<br />

Manual for installation and operation, <strong>Comfort</strong> <strong>211</strong> <strong>accu</strong> / <strong>solar</strong> GB (#73385) 49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!