Section 8 <strong>TM</strong> <strong>11</strong>-<strong>6625</strong>-<strong>2837</strong>-14 & P-7<br />

SERVICE SHEET 7 (Cont’d)<br />

Test 3. Check the reference diode A1OVR1, and Reference<br />

Amplifier AlOUl and their associated components. If the unit<br />

responds only to the local control or responds to remote<br />

control and not to the VERNIER, check the LCL/RMT input<br />

and the relay. If the reference output is incorrect in remote<br />

mode only, check the 1 dB Step Attenuator, relays, transistor<br />

switches, and other associated components. Small changes<br />

in RF Output level may be traceable to defective components<br />

coupled to the 10H input. If it was found that the amplitude<br />

modulation level varies with RF Output level, check the<br />

components associated with the AM Gain input. If the AM<br />

drive signal is reaching the RF Section, verify that it is<br />

reaching the A10 Assembly circuitry. Determine which<br />

component or part is defective, repair or replace it.<br />

Figure 8-17. A3 ALC Amplifier Assembly Component and Test Point Locations<br />

8-28B