5.2.8 Auto test<br />

On selection of this function, an automatic test is run on the machine functions, with results reported on the<br />

display. Before starting the test, all drawers and the tank must be inserted, all service doors closed and the relative<br />

recipients must be filledwith water and coffee.<br />

Test type Description Message if<br />

function OK<br />

Error message<br />

2.7.1 External ram<br />

test<br />

Check CPU ram successful ! failed !<br />

2.7.2 flash test Check CPU flash memory successful ! failed !<br />

2.7.3 Eeprom test Check non volatile memory with machine settings successful ! failed !<br />

2.7.4 rtc test Check real time clock successful ! failed !<br />

2.7.5 Cup lift test The motor-driven tray moves up and engages successful ! failed !<br />

upwards<br />

the upper microswitch<br />

2.7.6 cup lift test The motor-driven tray moves down and engages successful ! failed !<br />

downwards the lower microswitch<br />

2.7.7 Capp valve Check correct operation of the cappuccino valve successful ! failed !<br />

test<br />

and relative microswitch<br />

2.7.9 multivalve Check correct operation of multivalve and relative successful ! failed !<br />

test<br />

microswitches<br />

2.7.10 pump test Check pump and turbine operation.<br />

WARNING: hot water delivered<br />

successful ! failed !<br />

2.7.11 Grinder test Check grinderand coffee presenceè, as well as<br />

hall sensor which counts pulses.<br />

successful ! failed !<br />

2.7.12 Brew group Check of ascent of unit and activation of the successful ! failed !<br />

test upwards upper limit microswitch<br />

2.7.13 Brew group Check of descent of unit and activation of the successful ! failed !<br />

downwards lower limit microswitch.<br />

2.7.14 Water Check and inspection of power to coffee/ successful ! failed !<br />

heater test water boiler, if the sensor detects increase in<br />

temperature.<br />

2.7.15 Steam Check and inspection of power to steam boiler, if successful ! failed !<br />

heater test<br />

(Touch Plus<br />

only)<br />

the sensor detects increase in temperature.<br />

At the end of the automatic cycle, you can “repeat the automatic test” or “exit the test” as required.<br />

Exit diagnostics<br />

On selection of this option, the system exits the diagnostics menu and returns to the normal machine functions.<br />