5.4.5 Ring SYSTEM system SETTINGS settings<br />

parameters<br />

<strong>PRIMEA</strong> Chapter 05<br />

REV. 00 - Mar. 07<br />

Unit of<br />

measure Settings range Default value<br />

SETTING<br />

Water boiler temperature enabled °C 70 ... 150 130<br />

Water boiler temperature disabled °C 70 ... 150 115<br />

Steam boiler temperature enabled °C 70 ... 150 150<br />

Steam boiler temperature disabled °C 70 ... 150 130<br />

Normal cup temperature<br />

BEVERAGE PARAMETERS<br />

°C 70 ... 150 78<br />

Hot water flow rate (l/h) 5 ... 31 18<br />

Hot milk (pulse length) line-period 1 ... 9 5 (=100ms/50Hz)<br />

Hot milk (pulse period)<br />

MILK CIRCUIT RINSE<br />

20ms - steps 5 ... 250 60(=1200ms)<br />

Dispense time seconds 0 ... 40 10<br />

Pulse lenght line-period 1 ... 3 1 (= 20ms / 50Hz)<br />

Pulse period<br />

MILK CIRCUIT CLEANING<br />

20ms - steps 5 ... 250 15 (=300ms)<br />

Milk circuit cleaning (dispense time)<br />

MILK CIRCUIT CLEANING MESSAGES<br />

0 ... 40 10<br />

cleaning time seconds 30<br />

days before notification days 14<br />

days till block<br />

GRINDER SETTING<br />

days 21<br />

medium aroma pulses 60 ... 200 100<br />

Water reserve limit turbine pulses 0 ... 2000 750<br />

Stop coffee grounds nr. grounds 0 ... 25 24<br />

Coffee grounds counter nr. grounds 0 ... 25 24<br />

Descaling counter litres 0 300<br />

Serial number<br />