<strong>Sustainable</strong> <strong>Construction</strong> -<br />
Is submission of fire safety plan to the Relevant <strong>Authority</strong> required for a landed<br />
house?<br />
Fire safety plan proposals for small residential developments like detached, semi-detached,<br />
terraced and linked houses which do not exceed 3 storeys or levels (including basement and<br />
attic) are not required to be submitted to the Revelant <strong>Authority</strong> for approval as provided for<br />
under the Fire Safety (Exemption) Order 1994.<br />
The above exemption, however, does not mean that the QPs (Architects) need not<br />
comply with the relevant fire safety requirements in the Fire Code. The fire resistance<br />
requirement for such residential houses is usually half an hour for structures above<br />
ground and one hour for structures below ground. The QPs are to self-regulate and<br />
ensure that:<br />
(1) The buildings are designed with<br />
proper means of escape<br />
(2) Walls and fl oors are constructed of<br />
non-combustible materials, unless<br />
otherwise permitted in attics<br />
(3) Separating walls between units are<br />
properly constructed to prevent fi re<br />
spread<br />
It is important to note that such detached,<br />
semi-detached, terraced or linked houses<br />
refer to houses meant for single family<br />
occupation only.<br />
Small residential developments having more than 3 levels and townhouses<br />
are not covered by the Fire Safety (Exemption) Order 1994. Hence, SUB-<br />
MISSION OF FIRE SAFETY PLANS TO THE RELEVANT AUTHORITY IS REQUIRED.<br />