3 Installation<br />

22<br />

W0788<br />

3.7.8 Overload cut-off<br />

Description of system<br />

prevents an overload being lifted. If an overload has been established, the load can<br />

only be lowered. The switch is set in the factory. Corrections are only permissible<br />

in special cases, see page 57.<br />

In certain applications, wire rope hoists may also be used without an overload cutoff.<br />

However in this case they do not meet the requirements of the EU directives<br />

<strong>and</strong> are not marked with the CE symbol.<br />

Load measurement at rope anchorage<br />

With LET electronic sensor<br />

The overload cut-off is set to rated load +10%.<br />

Load measurement at gear<br />

With LEI electronic sensor<br />

The overload cut-off is set to rated load +10% overload.<br />

On stationary SH4 <strong>and</strong> SH5 wire rope hoists, remove the transport anchor screws<br />

marked in red after installation <strong>and</strong> before commissioning.<br />