3 Installation<br />
22<br />
W0788<br />
3.7.8 Overload cut-off<br />
Description of system<br />
prevents an overload being lifted. If an overload has been established, the load can<br />
only be lowered. The switch is set in the factory. Corrections are only permissible<br />
in special cases, see page 57.<br />
In certain applications, wire rope hoists may also be used without an overload cutoff.<br />
However in this case they do not meet the requirements of the EU directives<br />
<strong>and</strong> are not marked with the CE symbol.<br />
Load measurement at rope anchorage<br />
With LET electronic sensor<br />
The overload cut-off is set to rated load +10%.<br />
Load measurement at gear<br />
With LEI electronic sensor<br />
The overload cut-off is set to rated load +10% overload.<br />
On stationary SH4 <strong>and</strong> SH5 wire rope hoists, remove the transport anchor screws<br />
marked in red after installation <strong>and</strong> before commissioning.<br />
10.08<br />
BASH_02_1.FM