Wire Rope Hoists _ Operating and Maintenance ... - STAHL-POLSKA
Wire Rope Hoists _ Operating and Maintenance ... - STAHL-POLSKA
Wire Rope Hoists _ Operating and Maintenance ... - STAHL-POLSKA
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
6 Inspection <strong>and</strong> maintenance<br />
.<br />
38<br />
1/1<br />
2/2-1<br />
2/1<br />
4/2-1<br />
a [mm]<br />
50 Hz 60 Hz<br />
130 150<br />
70 80<br />
4/1 40 50<br />
6.6.5 Setting limit switch (continued)<br />
Switching point A↓ (S1)<br />
"Emergency limit switch bottom hook position"<br />
(Minimum clearance between rope guide (S) <strong>and</strong> clamping claws (K) for rope<br />
anchorage = 20 mm, see sketch)<br />
Set bottom hook position so that the bottom hook block does not touch the ground<br />
(would cause slack rope).<br />
Lower bottom hook block 2/1 to 120 mm, or 60 mm for 4/1, above desired hook<br />
position, if necessary turn setscrew (S1) to the left beforeh<strong>and</strong>.<br />
Turn setscrew (S1) to the right until contact S1 switches audibly.<br />
Check cut-off point in main <strong>and</strong> creep hoist.<br />
Switching point B↓ (S3)<br />
"Operational limit switch bottom hook position"<br />
(Minimum clearance to A↑ 120 mm for 2/1, 80 mm for 4/1)<br />
Lower bottom hook block 2/1 to 120 mm, or 60 mm for 4/1, above desired hook position,<br />
if necessary turn setscrew (S3) to the left beforeh<strong>and</strong><br />
Turn setscrew (S3) to the right until contact S3 switches audibly<br />
Check cut-off point in main <strong>and</strong> creep hoist.<br />
6.6.6 Servicing limit switch<br />
<strong>Maintenance</strong> work is restricted to checking the cut-off points. No maintenance or<br />
inspection is necessary for the gear limit switch itself.<br />
Any dust deposits that may be visible when the housing is opened must on no<br />
account be removed with compressed air as this would force the dust into the<br />
contacts <strong>and</strong> impair the switching function.<br />
On no account must benzene or other solvents be used to clean the limit switch!<br />
*1 Effective hook path with operational limit switch<br />
*2 Option<br />
Safety note:<br />
Incorrectly set limit switches may cause serious accidents!<br />
10.08<br />
BASH_02_1.FM