6 Inspection <strong>and</strong> maintenance<br />

.<br />

38<br />

1/1<br />

2/2-1<br />

2/1<br />

4/2-1<br />

a [mm]<br />

50 Hz 60 Hz<br />

130 150<br />

70 80<br />

4/1 40 50<br />

6.6.5 Setting limit switch (continued)<br />

Switching point A↓ (S1)<br />

"Emergency limit switch bottom hook position"<br />

(Minimum clearance between rope guide (S) <strong>and</strong> clamping claws (K) for rope<br />

anchorage = 20 mm, see sketch)<br />

Set bottom hook position so that the bottom hook block does not touch the ground<br />

(would cause slack rope).<br />

Lower bottom hook block 2/1 to 120 mm, or 60 mm for 4/1, above desired hook<br />

position, if necessary turn setscrew (S1) to the left beforeh<strong>and</strong>.<br />

Turn setscrew (S1) to the right until contact S1 switches audibly.<br />

Check cut-off point in main <strong>and</strong> creep hoist.<br />

Switching point B↓ (S3)<br />

"Operational limit switch bottom hook position"<br />

(Minimum clearance to A↑ 120 mm for 2/1, 80 mm for 4/1)<br />

Lower bottom hook block 2/1 to 120 mm, or 60 mm for 4/1, above desired hook position,<br />

if necessary turn setscrew (S3) to the left beforeh<strong>and</strong><br />

Turn setscrew (S3) to the right until contact S3 switches audibly<br />

Check cut-off point in main <strong>and</strong> creep hoist.<br />

6.6.6 Servicing limit switch<br />

<strong>Maintenance</strong> work is restricted to checking the cut-off points. No maintenance or<br />

inspection is necessary for the gear limit switch itself.<br />

Any dust deposits that may be visible when the housing is opened must on no<br />

account be removed with compressed air as this would force the dust into the<br />

contacts <strong>and</strong> impair the switching function.<br />

On no account must benzene or other solvents be used to clean the limit switch!<br />

*1 Effective hook path with operational limit switch<br />

*2 Option<br />

Safety note:<br />

Incorrectly set limit switches may cause serious accidents!<br />