14 Installation (for qualified installers only)<br />
Standard<br />
Ceiling with<br />
a Factory<br />
Built<br />
Chimney<br />
Cathedral<br />
Ceiling with<br />
a Factory<br />
Built<br />
Chimney<br />
Chimney Cap<br />
(See the section "Chimney<br />
Termination Requirements"<br />
for more details)<br />
Chimney Sections<br />
Insulation<br />
Follow the chimney<br />
manufacturer's instructions<br />
and clearances for floor<br />
penetrations. A ceiling<br />
support is required, an attic<br />
insulation shield is required<br />
where insulation is present.<br />
Chimney Connector Sections<br />
Floor Protection<br />
(See the section "Floor<br />
Protection Requirements"<br />
for more details)<br />
Chimney Cap<br />
(See the section "Chimney<br />
Termination Requirements"<br />
for more details)<br />
Chimney Sections<br />
Minimum Air Space to<br />
Combustibles (See Chimney<br />
Manufacturer's Instructions -<br />
usually 2")<br />
Floor Protection<br />
(See the section "Floor<br />
Protection Requirements"<br />
for more details)<br />
<br />
<br />
<br />
<br />
<br />
<br />
}<br />
<br />
<br />
<br />
Chimney<br />
Connector<br />
Sections<br />
<br />
<br />
<br />
Follow the chimney<br />
manufacturer's instructions<br />
and clearances for roof<br />
penetrations. A storm collar<br />
and flashing are required<br />
(some require a radiation<br />
shield).<br />
Minimum Air Space to<br />
Combustibles (See<br />
Chimney Manufacturer's<br />
Instructions - usually 2")<br />
Travis Industries 93508129 4020204<br />
}<br />
<br />
<br />
<br />
<br />
<br />
<br />
}<br />
Minimum 15'<br />
Maximum 33'<br />
<strong>Stove</strong> Clearances<br />
(See the section "<strong>Stove</strong><br />
Placement Requirements"<br />
for more details)<br />
Follow the chimney<br />
manufacturer's instructions<br />
and clearances for roof<br />
penetrations. A storm<br />
collar, flashing, and<br />
cathedral-style chimney<br />
support are required<br />
(some require a radiation<br />
shield).<br />
Minimum 15'<br />
Maximum 33'<br />
<strong>Stove</strong> Clearances<br />
(See the section "<strong>Stove</strong><br />
Placement Requirements"<br />
for more details)