8 Installation (for qualified installers only)<br />

Floor Protection Requirements<br />

• <strong>Stove</strong> must be placed on the included legs.<br />

Floor protection must be<br />

non-combustible and at least<br />

.018" thick (26 gauge).<br />

<br />

<br />

Min. 6”<br />

Min. 6”<br />

<br />

<br />

Min. 6”<br />

<br />

Min. 16”<br />

<br />

Minimum<br />

Minimum 37-7/8”<br />

<br />

38-3/4”<br />

<br />

NOTE : In corner installations with reduced-clearance connector, the clearance to the wall is less<br />

than 6". In this case, floor protection must extend to the wall.<br />

Leveling Bolts<br />

Make sure these rubber tipped<br />

bolts on each leg contact the floor<br />

(they dampen any noise that may<br />

transmit through the hearth). Do<br />

not adjust with weight on the legs,<br />

the rubber tips may tear.<br />

Travis Industries 93508129 4040915