16 Installation (for qualified installers only)<br />
Hearth<br />
<strong>Stove</strong><br />
Direct<br />
Connection<br />
NOTE:<br />
Direct<br />
connections<br />
require installation<br />
of an airtight, noncombustible<br />
block-off plate or<br />
damper adapter.<br />
Interior or<br />
Exterior<br />
Masonry<br />
Chimney<br />
NOTE:<br />
This type of<br />
installation<br />
requires a UBC<br />
approved<br />
masonry<br />
connector or a<br />
factory built (U.L.<br />
Listed) wall<br />
thimble.<br />
NOTE: The chimney must have a clay<br />
tile liner. If it does not, the installation<br />
must use a positive connection (full<br />
reline). The entire fireplace and<br />
chimney must be clean, undamaged,<br />
and meet all local building codes (UBC,<br />
etc.). Damage must be repaired prior<br />
to installation. The chimney must be<br />
15' to 33' tall.<br />
Combustible<br />
Mantle<br />
Floor Protection<br />
(See the section "Floor<br />
Protection Requirements"<br />
for more details)<br />
NOTE: The chimney must have a<br />
clay tile liner. If it does not, the<br />
installation must use a positive<br />
connection (full reline). The<br />
entire fireplace and chimney must<br />
be clean, undamaged, and meet<br />
all local building codes (UBC,<br />
etc.). Damage must be repaired<br />
prior to installation. The chimney<br />
must be 15' to 33' tall.<br />
See the section "<strong>Stove</strong><br />
Placement Requirements" for<br />
minimum clearances required.<br />
Chimney connector sections<br />
See the section<br />
"Floor Protection<br />
Requirements"<br />
Min. 18"<br />
Min. 18"<br />
clearance<br />
to ceiling<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Clay<br />
Liner<br />
Stainless steel<br />
chimney connector<br />
must Extend 1' past<br />
the block-off plate or<br />
to the flue liner<br />
Airtight<br />
Insulated<br />
Clean-Out<br />
Remove damper<br />
or wire it open<br />
Block-off plate or<br />
damper adapter<br />
See the section<br />
"<strong>Stove</strong> Placement<br />
Requirements" for<br />
minimum clearances<br />
required.<br />
Clay Liner<br />
This type of<br />
installation requires<br />
a UBC approved<br />
masonry connector<br />
or a factory built<br />
(U.L. Listed) wall<br />
thimble.<br />
Make sure the<br />
clean-out seals in<br />
place.<br />
Travis Industries 93508129 4020204