2.1 Electrostatic Discharge<br />

0002M621-15<br />

2<br />

Setup<br />

This chapter describes the physical layout of the board, the setup process, and<br />

how to check for proper operation once the board has been installed. This chapter<br />

also includes troubleshooting, service, and warranty information.<br />

Before you begin the setup process, please remember that electrostatic discharge<br />

(ESD) can easily damage the components on the <strong>BajaPPC</strong>-<strong>750</strong>. Electronic devices,<br />

especially those with programmable parts, are susceptible to ESD, which can<br />

result in operational failure. Unless you ground yourself properly, static charges<br />

can accumulate in your body and cause ESD damage when you touch the board.<br />

CAUTION. Use proper static protection and handle the <strong>BajaPPC</strong>-<strong>750</strong><br />

board only when absolutely necessary. Always wear a wriststrap<br />

to ground your body before touching the board. Keep<br />

your body grounded while handling the board. Hold the<br />

board by its edges—do not touch any components or circuits.<br />

When the board is not in an enclosure, store it in a staticshielding<br />

bag.<br />

To ground yourself, wear a grounding wriststrap. Simply placing the board on top<br />

of a static-shielding bag does not provide any protection—place it on a grounded<br />

dissipative mat. Do not place the board on metal or other conductive surfaces.