<strong>ADuM3190</strong> Data Sheet<br />

ABSOLUTE MAXIMUM RATINGS<br />

TA = 25°C, unless otherwise noted.<br />

Table 7.<br />

Parameter Rating<br />

Storage Temperature (TST) Range −65°C to +150°C<br />

Ambient Operating Temperature<br />

(TA) Range<br />

−40°C to +125°C<br />

Junction Temperature<br />

Supply Voltages<br />

−40°C to +150°C<br />

VDD1, VDD2 1 −0.5 V to +24 V<br />

VREG1, VREG2 1 −0.5 V to +3.6 V<br />

Input Voltages (+IN, −IN)<br />

Output Voltages<br />

−0.5 V to +3.6 V<br />

REFOUT, COMP, REFOUT1, EAOUT −0.5 V to +3.6 V<br />

EAOUT2 −0.5 V to +5.5 V<br />

Output Current per Output Pin −11 mA to +11 mA<br />

Common-Mode Transients2 −100 kV/μs to +100 kV/μs<br />

1 All voltages are relative to their respective grounds.<br />

2 Refers to common-mode transients across the insulation barrier. Commonmode<br />

transients exceeding the absolute maximum ratings may cause<br />

latch-up or permanent damage.<br />

<strong>Rev</strong>. 0 | Page 6 of 16<br />

Stresses above those listed under Absolute Maximum Ratings<br />

may cause permanent damage to the device. This is a stress<br />

rating only; functional operation of the device at these or any<br />

other conditions above those indicated in the operational<br />

section of this specification is not implied. Exposure to absolute<br />

maximum rating conditions for extended periods may affect<br />

device reliability.<br />

Table 8. Maximum Continuous Working Voltage 1<br />

Parameter Max Unit Constraint<br />

WAVEFORM<br />

AC Voltage<br />

Bipolar 560 V peak 50-year minimum lifetime<br />

Unipolar 1131 V peak 50-year minimum lifetime<br />

DC Voltage 1131 V peak 50-year minimum lifetime<br />

1 Refers to continuous voltage magnitude imposed across the isolation<br />

barrier. See the Insulation Lifetime section for more details.<br />

ESD CAUTION