30.09.2012 Views

Version List

Version List

Version List

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Transceiver module TRX433-10C2 / TRX868-10C2 (Vers. 1.0E) 10<br />

Examples of data flow<br />

Following, there are some examples by which you can see the data flow by different configuration of Fast<br />

send, CRC16, Handshake etc.<br />

Examples for different configuration of fast send and CRC16<br />

Refer to the figure for the data flow which depends on the configuration of Fast send and CRC16. Thereby,<br />

module 1 is used as transceiver and module 2 is used as receiver. Of course several modules with the same<br />

configuration as the transceiver can receive the data signal.<br />

module 1<br />

module 2<br />

RS232, RxD-pin<br />

RF-transmission<br />

RS232, TxD-pin<br />

Byte 1<br />

Byte 2<br />

Byte 3<br />

Byte 4<br />

start RF-transmission<br />

after 2-3 bytes break<br />

32 Bit<br />

Preamble<br />

+2ms<br />

Startup<br />

24 Bit<br />

SYNC<br />

Length<br />

Byte 1<br />

Byte 2<br />

Byte 3<br />

Byte 4<br />

CRC16<br />

Figure 3 Dataflow without Fast send with CRC16, RF data rate > RS232-baud rate<br />

module 1<br />

module 2<br />

RS232, RxD-pin<br />

RF-transmission<br />

RS232, TxD-pin<br />

Byte 1<br />

Byte 2<br />

Byte 3<br />

Byte 4<br />

start RF-transmission<br />

after 2-3 bytes break<br />

32 Bit<br />

Preamble<br />

+2ms<br />

Startup<br />

24 Bit<br />

SYNC<br />

Length<br />

Byte 1<br />

Byte 2<br />

Byte 3<br />

Byte 4<br />

Byte 1<br />

Byte 2<br />

Byte 1<br />

Byte 3<br />

output after first<br />

received databyte<br />

Figure 4 Dataflow without Fast send without CRC16, RF data rate > RS232-baud rate<br />

module 1<br />

module 2<br />

RS232, RxD-pin<br />

RF-transmission<br />

RS232, TxD-pin<br />

Byte 1<br />

Byte 2<br />

Byte 3<br />

Byte 4<br />

start RF-transmission<br />

after 2-3 bytes break<br />

2<br />

32 Bit<br />

Byte<br />

Preamble<br />

24 Bit<br />

+2ms Startup<br />

SYNC<br />

Figure 5 Dataflow without Fast send without CRC16, RF data rate < RS232-baud rate<br />

Length<br />

Byte 1<br />

Byte 1<br />

Byte 2<br />

Byte 3<br />

Byte 3<br />

Byte 4<br />

Byte 4<br />

output after first<br />

received databyte<br />

Byte 2<br />

Byte 3<br />

output after<br />

checked CRC16<br />

Byte 4<br />

Byte 4