Version List
Version List
Version List
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Transceiver module TRX433-10C2 / TRX868-10C2 (Vers. 1.0E) 32<br />
_____________________________________________________________________________________<br />
Functional name READ hardware version Function 00H<br />
Functional call 0B0H, 00H, 03H<br />
Answer 00H, HVERS<br />
This is part of the module designation and is comprised of assembly variants and module type.<br />
The number 10 in TRX433-10C2 marks the hardware version 10.<br />
The transceiver is produced in multiple assembly variants.<br />
HVERS = 0AH: 16MHz µP clock frequency, internal voltage regulator 3.3V, loop filter 19.2kbaud<br />
HVERS = 0BH: 8MHz µP clock frequency, internal voltage regulator 3.0V, loop filter 19.2kbaud<br />
HVERS = 0CH: 16MHz µP clock frequency, without internal voltage regulator, loop filter 19.2kbaud<br />
HVERS = 0DH: 8MHz µP clock frequency, without internal voltage regulator, loop filter 19.2kbaud<br />
HVERS = 0EH: 8MHz µP clock frequency, internal voltage regulator 3.3V, loop filter 19.2kbaud<br />
There might accrue other hardware versions in future. See coding marking of the transceiver module.<br />
________________________________________________________________________________<br />
Functional name READ Frequency version Function 00H<br />
Functional call 0B0H, 00H, 04H<br />
Answer 00H, FVERS<br />
Frequency - version of the transceiver. This is part of the module designation.<br />
The Numbers 433 marks the frequency version in TRX433-10C2.<br />
FVERS = 0: 433 MHz band, 433.0625 - 434.7875MHz<br />
FVERS = 1: 868 MHz band, 868.0125 - 869.9875MHz<br />
FVERS = 2: 915 MHz band, 914.0125 - 915.9875MHz<br />
See coding marking of the transceiver module.<br />
_____________________________________________________________________________________<br />
Functional name READ serial number Function 00H<br />
Functional call 0B0H, 00H, 05H<br />
Answer 00H, SER0, SER1, SER2, SER3<br />
32bit unique serial number of the transceiver.<br />
SER0 = LSB, SER3 = MSB of the 32 bit-serial number<br />
See coding marking of the transceiver module.<br />
_____________________________________________________________________________________