Transceiver module TRX433-10C2 / TRX868-10C2 (Vers. 1.0E) 47<br />

_____________________________________________________________________________________<br />

Functional name WRITE calibrate now Function 21H<br />

Functional call 0B0H, 21H, 00H<br />

Answer 21H, 00H immediately when calibration starts<br />

21H, 01H after typ. 50ms, when calibration ends successfully<br />

resp. 21H, 00H immediately when calibration starts.<br />

21H, 02H after typ. 250ms, if calibration was not successful<br />

Starts immediately a VCO-calibration. If the transceiver module is in the configuration mode then the start<br />

and the ending will be reported just as the result of the calibration. Normally, the calibration takes about<br />

50ms i.e. it’s straightaway finished successfully. If the first try wasn’t successful then the transceiver tries to<br />

recalibrate up to five times. Therefore the calibration can take from 50ms up to 250ms.<br />

When a calibration was not successful then the call can be repeated.<br />

_____________________________________________________________________________________