Offset<br />

28 (lC) 1<br />

29 (lC) • 1<br />

28 (lC) 1<br />

29 (lD) • 1<br />

30 (lE) •• 2<br />

Bytes and Field<br />

Alignment Name<br />

1. •• • •••<br />

• 1 ••<br />

•• 1.<br />

••. 1<br />

.1 ••<br />

.•• 1<br />

x.x.<br />

IOBCRDCC<br />

IOBCRILC<br />

10 BERRC T<br />

Byte 1<br />

Byte 2<br />

1111 1 •••<br />

.000<br />

• ••• .010<br />

.011<br />

.110<br />

.111<br />

.101<br />

INPUT/OUTPUT BLOCK<br />

Field Description, Contents, Meaning<br />

STANDARD FIELDS (Continued)<br />

BTAM:<br />

SAD or ENABLE issued by OPEN resulted in a permanent<br />

I/O error. If the lOB is for a local 3270 device,<br />

this bit indicates that OPEN did not initialize the<br />

device because it was being used by OLTEP.<br />

This lOB is currently in use by an I/O operation •<br />

RVI was received. (3270) •<br />

RFT received from control unit capable of general<br />

poll (3270). Request-for-test message from a remote<br />

3270.<br />

Turned on after a remote 3270 error status message<br />

has been processed.<br />

Line is under on-line test operation •<br />

(Reserved bits)<br />

BTAM used for timer value (OPEN and LOPEN).<br />

Optical Reader: Data check error count.<br />

Optical Reader: Incorrect length error count.<br />

Error counter (local 3270 only).<br />

The local 3270 ERP uses this byte to keep a count of<br />

retry attempts.<br />

The local 3270 ERP uses these bits as flags during<br />

retry attempts.<br />

If bit 5 of IOBFLAGl is off, the local 3270 ERP has<br />

recovered from the error. If on, the local 3270 ERP<br />

has not processed the error.<br />

The local 3270 ERP could not recover from the error.<br />

The problem program must reconstruct the buffer<br />

image.<br />

The local 3270 ERP determined that the error is<br />

permanent and non-recoverable.<br />

The local 3270 ERP determined that the channel<br />

program or data stream builder of the problem program<br />

can recover from the error.<br />

The local 3270 ERP determined that the local 3270<br />

channel end/abnormal appendage should perform retry.<br />

The local 3270 channel end/abnormal end appendage is<br />

attempting to recover from the error by retrying the<br />

channel program.<br />

Note: Every BSC2 lOB has been extended for 8 bytes; the extension will contain the 3275<br />

Dial terminal ID received during connection.<br />

BTAM EXTENSION<br />

EXTENSION SEGMENTS<br />

32 (20) 1 10 BUCBX UCB index. The line number is used as an index to<br />

locate the proper UCB address in the DEB.<br />

33 (21) . 5 IOBWORK Work area used by error routines and on-line terminal<br />

test routines.<br />

38 (26) . . 1 IOBRCVPT Received ACK (ACK-O or ACK-l).<br />

216 OS <strong>System</strong> <strong>Control</strong> <strong>Blocks</strong> (Release 21.7)