02.07.2013 Views

System Control Blocks

System Control Blocks

System Control Blocks

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Byte and Field<br />

Offset Alignment Name<br />

-32 (-20) 32 TCBFRS<br />

o (0) 4<br />

4 (4) 4<br />

8 (8) 4<br />

12 (C) 4<br />

16 (10) 4<br />

16 (10) 1<br />

11 (11) • 3<br />

20 (14) 4<br />

20 (14) 1<br />

21 (15) • 3<br />

TCBRBP<br />

TCBPIE<br />

TCBDEB<br />

TCBTIO<br />

TCBCMP<br />

Byte 1<br />

1 •••<br />

• 1 •.<br />

• .xx xxxx<br />

Bytes 2-4<br />

TCBTRN<br />

TCBFLTRN<br />

1 •••<br />

. 1 •.<br />

· .1.<br />

• •• 1 1 ...<br />

.1 ..<br />

.• 1.<br />

••• x<br />

326 OS <strong>System</strong> <strong>Control</strong> <strong>Blocks</strong> (Release 21.1)<br />

TASK CONTROL BLOCK -- MVT<br />

Hex.<br />

Dig. Field Description, Contents, Meaning<br />

Floating point register save area.<br />

Address of the RB for executing program.<br />

Address of the program interrupt element (PIE).<br />

Address of the queue of DEBs.<br />

Address of the task I/O table (TIOT).<br />

Task completion code.<br />

A flag byte field containing indicators used or set<br />

by the ABEND SVC.<br />

A dump has been requested.<br />

A step ABEND has been requested •<br />

Reserved.<br />

<strong>System</strong> completion code in first 12 bits; user<br />

completion code in last 12 bits.<br />

These codes are explained in the manual, IBM<br />

<strong>System</strong>/360 Operating <strong>System</strong>: Messages and Codes,<br />

GC28-6631, under the heading -<strong>System</strong> Completion<br />

Codes.-<br />

Flag byte.<br />

Both TESTRAN and decimal simulator programs being<br />

used on a Model 91 machine.<br />

Suppress takinq checkpoints for this step •<br />

Job step TeB:<br />

This is a graphics foreground job or the graphic job<br />

processor.<br />

This is a 1094 emulator task on a Model 85.<br />

TCBTCPp-Task to be posted, but currently rolled out.<br />

TCBTSTCP - This is a time-shared task under control<br />

of the TEST command processor.<br />

TCBOLTEP - OLTEP functions require clean-up before<br />

abnormal termination can be invoked.<br />

(Reserved bits)<br />

1. If this task is not operating under TSO and SVC<br />

61 has been issued, this field contains the<br />

address of the control Core table for TESTRAN.<br />

2. If this task is operating under TSO and SVC 61<br />

has been issued, this field contains one of the<br />

following:<br />

a.) The address of an SVC information block (if<br />

the task is not a subtask of the TEST<br />

command processor).<br />

b.) The address of the test communication table<br />

(TCOMTAB) in the TEST command processor (if<br />

the task is a subtask of the TEST command<br />

processor).<br />

3. If this task is the Test/TMP task operating under<br />

TSO, and TEST initialization has been executed,<br />

this task contains the address of the test<br />

communication table (TCOMTAB) in the TEST command<br />

processor. In this case, the test communication<br />

table may point to one or more SVC information<br />

blocks.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!