EIP-5000/5000L<br />

Temperature<br />

warning<br />

indicator<br />

Lamp<br />

indicators<br />

1, 2<br />

Power<br />

indicator<br />

Info<br />

Maintenance indicator<br />

Normal Abnormal<br />

Off<br />

Red on<br />

(Standby)<br />

Green on Red on<br />

Green blinks<br />

when the lamp<br />

is warming up.<br />

Red on<br />

(Standby)<br />

Green on/<br />

Red on<br />

Green<br />

blinks<br />

Problem Cause Possible solution<br />

The internal<br />

temperature is<br />

abnormally high.<br />

The lamp does<br />

not illuminate.<br />

Time to change<br />

the lamp.<br />

Thelampdoes<br />

not illuminate.<br />

The power<br />

indicator blinks in<br />

green when the<br />

projector is on.<br />

• Blocked air intake<br />

• Cooling fan breakdown<br />

• Internal circuit failure<br />

• Clogged air intake<br />

• Clogged intake vent<br />

cover<br />

• The lamp is shut<br />

down abnormally.<br />

• Remaining lamp life<br />

be<strong>com</strong>es 5% or less.<br />

• Burnt-out lamp<br />

• Lamp circuit failure<br />

• The intake vent<br />

cover is open.<br />

1 – 11<br />

• Relocate the projector to an area<br />

with proper ventilation.<br />

• Take the projector to your nearest<br />

EIKI Authorized Dealer or Service<br />

Center for repair.<br />

• Clean the air vents and the intake<br />

vent cover.<br />

• Disconnect the power cord from<br />

the AC outlet, and then connect it<br />

again.<br />

• Carefully replace the lamp.<br />

• Take the projector to your nearest<br />

EIKI Authorized Dealer or Service<br />

Center for repair.<br />

• Please exercise care when<br />

replacing the lamp.<br />

• Securely install the cover.<br />

• If the power indicator blinks even<br />

when the intake vent cover is<br />

securely installed, contact your<br />

nearest EIKI Authorized Dealer or<br />

Service Center for advice.<br />

• If the temperature warning indicator blinks and the projector enters the standby mode, the temperature<br />

warning indicator starts to illuminate. Check whether any of the ventilation holes are blocked<br />

and then try turning the power back on. Wait until the projector has cooled down <strong>com</strong>pletely before<br />

plugging in the power cord and turning the power back on. (At least 10 minutes.)<br />

• If the power is turned off for a brief moment due to power outage or some other cause while using the<br />

projector, and the power supply recovers immediately after that, the lamp indicator will illuminate in red<br />

and the lamp may not be lit. In this case, unplug the power cord from the AC outlet, replace the power<br />

cord in the AC outlet and then turn the power on again.<br />

• The cooling fan keeps the internal temperature of the projector constant and this function is controlled<br />

automatically. The sound of the cooling fan may change during operation because the fan speed may<br />

change and this is not a malfunction.