Technical Data<br />

Scan unit Galvanometer scanner:FireSCAN<br />

Aperture: 10 mm<br />

Scanning speed: < 5 m/sec<br />

Beam source dimensions incl.<br />

scanner<br />

Operation and Storage<br />

Conditions<br />

Focusing objectives, optional:<br />

F-Theta 100<br />

Spot diameter (1) : 25 µm<br />

Marking field size: 60 x 60 mm<br />

Focusing length: 142 ± 3 mm from lower edge of scan unit<br />

F-Theta 163<br />

Spot diameter (1) : 35 µm<br />

Marking field size: 110 x 110 mm<br />

Focusing length: 220 ± 3 mm from lower edge of scan unit<br />

F-Theta 254<br />

Spot diameter (1) : 50 µm<br />

Marking field size: 180 x 180 mm<br />

Focusing length: 400 ± 5 mm from lower edge of scan unit<br />

(1) Deviations may occur with different materials.<br />

Length x width x height:740 x 201 x 233 mm<br />

Weight: 20 kg<br />

<strong>Operating</strong> temperature: 25 °C ± 10 °C<br />

Storage temperature: 10 °C to 50 °C<br />

Air humidity: maximum 85%, non-condensing,<br />

non-corroding<br />

34 <strong>Operating</strong> <strong>Instructions</strong> DPLMagic/Genesis/Nexus <strong>Marker</strong> - 08/2006