Hydr<strong>on</strong>ic bal<strong>an</strong>ce of the apartment’s heating circuit<br />

Distributi<strong>on</strong> <strong>system</strong> must ensure that<br />

thermal energy is available for the c<strong>on</strong>sumer<br />

at all times <strong>an</strong>d loads, at the right<br />

temperature <strong>an</strong>d the right differential<br />

pressure.<br />

The required differential pressure must<br />

be ensured at all relev<strong>an</strong>t points of a<br />

distributi<strong>on</strong> <strong>system</strong>, beginning <strong>with</strong> the<br />

energy producti<strong>on</strong>, right through to the<br />

least favorable radiator. Installati<strong>on</strong> of<br />

a differential pressure c<strong>on</strong>troller in the<br />

apartment heating circuit guar<strong>an</strong>tees<br />

fault free hydr<strong>on</strong>ic c<strong>on</strong>diti<strong>on</strong>s.<br />

21°C<br />

A str<strong>on</strong>g opini<strong>on</strong>, which still exists<br />

around, that a heating <strong>system</strong> c<strong>an</strong> be<br />

properly bal<strong>an</strong>ced <strong>with</strong> secti<strong>on</strong> m<strong>an</strong>ual<br />

bal<strong>an</strong>cing valves <strong>an</strong>d regulated pumps<br />

<strong>on</strong>ce again proved to be err<strong>on</strong>eous in<br />

practice.<br />

In additi<strong>on</strong> to a correctly set differential<br />

pressure c<strong>on</strong>troller for the apartment<br />

heating circuit, the individual radiator<br />

valves must also be correctly preset.<br />

St<strong>an</strong>dard compli<strong>an</strong>t differential pressures<br />

in fr<strong>on</strong>t of the radiator valves now<br />

make flow noises a thing of the past.<br />

21°C 21°C<br />

21°C 21°C 21°C<br />

21°C 21°C 21°C<br />

19<br />

What is the EvoFlat <strong>system</strong> soluti<strong>on</strong><br />

The heating side c<strong>on</strong>necti<strong>on</strong> is made<br />

<strong>with</strong>out <strong>an</strong>y <strong>system</strong> separati<strong>on</strong>. The<br />

heating circuit supply must be fitted<br />

<strong>with</strong> a differential pressure c<strong>on</strong>troller to<br />

guar<strong>an</strong>tee optimum pressure c<strong>on</strong>diti<strong>on</strong>s<br />

<strong>an</strong>d flows in the heating <strong>system</strong>. The<br />

room temperature is c<strong>on</strong>trolled <strong>with</strong><br />

radiator thermostats. With the mounting<br />

of a thermal actuator <strong>with</strong> installed<br />

z<strong>on</strong>e valve <strong>an</strong>d using central m<strong>an</strong>ual<br />

or programmable room thermostat<br />

enables a c<strong>on</strong>venient, energy optimized<br />

c<strong>on</strong>trol of the heating.<br />

Example of well bal<strong>an</strong>ced heat<br />

distributi<strong>on</strong><br />

• Proper c<strong>on</strong>trol of flow <strong>an</strong>d pressure<br />

to each flat <strong>with</strong> differential<br />

pressure c<strong>on</strong>troller<br />

• proper temperature in each room<br />

secured <strong>with</strong> pre-setting valves<br />

<strong>with</strong> thermostat sensor <strong>on</strong> each<br />

radiator<br />

Differential pressure c<strong>on</strong>troller is part<br />

of each flat stati<strong>on</strong>