Water heater<br />

4.2.1 Termix Novi<br />

Domestic hot water (DHW)<br />

Substati<strong>on</strong><br />

type<br />

Novi Type 1<br />

Novi Type 2<br />

Heat exch<strong>an</strong>ger<br />

XB06-H-26<br />

IHPT 3.0<br />

XB06-H-40<br />

IHPT 3.0<br />

DHW Capacity<br />

kW<br />

EXTENSION OPTIONS:<br />

• Cover, grey-lacquered steel<br />

(Designed by Jacob Jensen)<br />

• Safety valve<br />

• GTU pressure equalizer, eliminates<br />

safety valve discharge piping<br />

• Ball valves <strong>on</strong> all c<strong>on</strong>necti<strong>on</strong>s<br />

• Booster pump (increases DH flow)<br />

• Circulati<strong>on</strong> pipe/c<strong>on</strong>necti<strong>on</strong> <strong>with</strong><br />

n<strong>on</strong>-return valve<br />

TECHNICAL PARAMETERS:<br />

Nominal pressure: PN 16<br />

DH supply temperature: T = 120 °C<br />

max<br />

DCW static pressure: p = 1.5 bar<br />

min<br />

Brazing material (HEX): Copper<br />

Weight incl. cover: 7-9 kg<br />

(incl. packing)<br />

Cover: Greylacquered<br />

steel<br />

DHW: Capacity examples<br />

Supply flow<br />

Primary °C<br />

33<br />

Return flow<br />

Primary °C<br />

Introducti<strong>on</strong> to the product r<strong>an</strong>ge<br />

Dimensi<strong>on</strong>s (mm):<br />

With insulati<strong>on</strong>:<br />

H 432 x W 300 x D 155<br />

With cover:<br />

H 442 x W 315 x D 165<br />

Pipes dimensi<strong>on</strong>s (mm):<br />

Primary: Ø 18<br />

Sec<strong>on</strong>dary: Ø 18<br />

C<strong>on</strong>necti<strong>on</strong>s sizes:<br />

DH + DCW + DHW: G ¾”<br />

(ext. thread)<br />

DHW °C<br />

Pressure loss<br />

Primary kPa*<br />

DHW Tap load<br />

l/min<br />

32.3 60 19.8 10/45 20 13,3<br />

40.3 60 20.7 10/45 29 16,6<br />

43 70 17.4 10/45 20 17,7<br />

53 70 18.5 10/45 29 21,8<br />

29 60 24.3 10/50 20 10,5<br />

60 24.6 10/50 29 12,6<br />

41 70 19.6 10/50 20 14,8<br />

50 70 20.8 10/50 29 18,0<br />

32.3 55 21.9 10/45 22 13,3<br />

38 55 22.2 10/45 30 15,7<br />

38 60 19.6 10/45 20 15,7<br />

48.7 60 19.6 10/45 32 20,1<br />

50 70 16.4 10/45 20 20,6<br />

57 70 17.1 10/45 32 23,3<br />

34 60 23.4 10/50 20 12,3<br />

44 60 24.1 10/50 32 15,9<br />

48 70 18.8 10/50 20 17,3<br />

61.5 70 19.4 10/50 32 22,2<br />

(Please c<strong>on</strong>tact <strong>your</strong> local D<strong>an</strong>foss representative for capacity examples at other temperature c<strong>on</strong>diti<strong>on</strong>s)