Introducti<strong>on</strong><br />

1.2 Documented benefits of EvoFlat <strong>system</strong>s<br />

Low overall costs<br />

The idea behind the decentralized<br />

<strong>system</strong> for heating <strong>an</strong>d domestic hot<br />

water is not new, <strong>an</strong>d the adv<strong>an</strong>tages<br />

<strong>an</strong>d benefits of opting for such <strong>system</strong>s<br />

are well documented.<br />

Encourage people to save <strong>on</strong> energy<br />

When residents <strong>an</strong>d ten<strong>an</strong>ts <strong>on</strong>ly pay<br />

for what they use, they tend to keep a<br />

critical eye <strong>on</strong> their energy c<strong>on</strong>sumpti<strong>on</strong>.<br />

A study carried out in Denmark in<br />

1991-2005 examined the actual energy<br />

c<strong>on</strong>sumpti<strong>on</strong> before <strong>an</strong>d after individual<br />

meters were installed.<br />

The results clearly showed that individual<br />

metering signific<strong>an</strong>tly reduces energy<br />

c<strong>on</strong>sumpti<strong>on</strong> per square metre<br />

– normally by as much as 15-30%.<br />

Reduce energy loss<br />

A 2008 study compared the different<br />

distributi<strong>on</strong> <strong>system</strong>s available for apartment<br />

blocks <strong>an</strong>d multi-family houses.<br />

The calculati<strong>on</strong>s were based <strong>on</strong> a<br />

4-storey building <strong>with</strong> eight 133-squaremetre<br />

apartments per storey. The figures<br />

compared a EvoFlat soluti<strong>on</strong> <strong>with</strong> a<br />

single vertical riser pipe <strong>system</strong> <strong>an</strong>d a<br />

<str<strong>on</strong>g>Take</str<strong>on</strong>g> up less space<br />

As the name suggests, EvoFlat <strong>system</strong>s<br />

take up very little space. Compared to<br />

individual gas-fuelled boilers, which are<br />

often combined <strong>with</strong> a storage t<strong>an</strong>k, a<br />

flat stati<strong>on</strong> takes up about 80% less<br />

space <strong>an</strong>d c<strong>an</strong> normally be mounted in<br />

a wall recess or small cupboard.<br />

MWh/100M 2<br />

The main benefits <strong>with</strong> decentralized<br />

<strong>system</strong>s include lower energy c<strong>on</strong>sumpti<strong>on</strong><br />

as a result of individual metering,<br />

more revenue-generating space in<br />

apartment blocks <strong>an</strong>d multi-family<br />

25<br />

20<br />

15<br />

10<br />

5<br />

Meters introduced Meters introduced<br />

Housing associati<strong>on</strong> “Hyldespjældet”<br />

Individual metering since 01.98<br />

horiz<strong>on</strong>tal riser pipe <strong>system</strong> <strong>with</strong><br />

centralized producti<strong>on</strong> of domestic hot<br />

water. The study showed that compared<br />

to modern centralized domestic hot water<br />

soluti<strong>on</strong>s, a EvoFlat soluti<strong>on</strong> reduces<br />

heat loss from the pipes by more th<strong>an</strong><br />

40% <strong>an</strong>d by as much as 80% compared<br />

to traditi<strong>on</strong>al <strong>on</strong>e-pipe soluti<strong>on</strong>s.<br />

Admittedly, flat stati<strong>on</strong>s do take up a little<br />

more space th<strong>an</strong> centralized <strong>system</strong>s<br />

for domestic hot water producti<strong>on</strong>,<br />

although they are still very unobtrusive.<br />

In return, however, they free up c<strong>on</strong>siderable<br />

amounts of space in basement<br />

areas.<br />

5<br />

Introducti<strong>on</strong><br />

houses, <strong>an</strong>d reducti<strong>on</strong>s in the amount of<br />

heat wasted in l<strong>on</strong>g pipe runs. Here are<br />

some factual numbers.<br />

MWh/100M 2<br />

0<br />

0<br />

1991 1998 2005 1991 2000 2005<br />

kWh<br />

m 3<br />

25<br />

20<br />

15<br />

10<br />

5<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

0.35<br />

0.3<br />

0.25<br />

0.2<br />

0.15<br />

0.1<br />

0.05<br />

0<br />

Housing associati<strong>on</strong> “Morbærhaven”,<br />

Individual metering since 01.00<br />

Single vertical<br />

pipe <strong>system</strong><br />

Individual<br />

gas boiler<br />

Horiz<strong>on</strong>tal pipe<br />

<strong>system</strong> <strong>with</strong><br />

central DHW<br />

producti<strong>on</strong><br />

EvoFlat<br />

EvoFlat Central<br />

domestic hot<br />

water<br />

Individual gas boiler: 0.32.<br />

Boiler (0.15 m 3 ) + chimney (0.17 m 3 )<br />

EvoFlat: 0.062. Flat stati<strong>on</strong> (0.062 m 3 )<br />

Central domestic hot water: 0.02.<br />

Water meter (0.01 m 3 ) + heat meter (0.01 m 3 )<br />

* Storage t<strong>an</strong>k in basement will take up signific<strong>an</strong>tly<br />

more space th<strong>an</strong> in a EvoFlat soluti<strong>on</strong>