What is the EvoFlat <strong>system</strong> soluti<strong>on</strong>?<br />

3.5.3 Additi<strong>on</strong>al flat stati<strong>on</strong> comp<strong>on</strong>ents<br />

3. Differential pressure c<strong>on</strong>troller<br />

(0.1 bar)<br />

This comp<strong>on</strong>ent ensures a c<strong>on</strong>st<strong>an</strong>t<br />

differential pressure <strong>with</strong>in the entire<br />

apartment installati<strong>on</strong> (heating 5-25<br />

kPa), <strong>an</strong>d optimum functi<strong>on</strong>ing of the<br />

radiator thermostats. Every radiator<br />

is therefore optimally supplied <strong>with</strong><br />

heat – reliably <strong>an</strong>d quietly.<br />

4. Heat meter<br />

All EvoFlat flat stati<strong>on</strong>s are prepared<br />

for the installati<strong>on</strong> of water <strong>an</strong>d heat<br />

meters. The use of direct immersi<strong>on</strong><br />

sensors is secured.<br />

Heat meter, installed in flat stati<strong>on</strong>,<br />

is <strong>an</strong> ultras<strong>on</strong>ic device for measuring<br />

the c<strong>on</strong>sumpti<strong>on</strong> of thermal energy.<br />

It c<strong>on</strong>sists of:<br />

-calculator <strong>with</strong> integral hardware<br />

<strong>an</strong>d software for measuring flow rate,<br />

temperature <strong>an</strong>d energy c<strong>on</strong>sumpti<strong>on</strong>,<br />

-ultras<strong>on</strong>ic flow sensor,<br />

-two temperature sensors.<br />

Dynamic r<strong>an</strong>ge measurement is<br />

1:250. Minimum flow rate for which<br />

is guar<strong>an</strong>teed measurement accuracy,<br />

according to EN1434, is 6 l/h. If<br />

equipped <strong>with</strong> <strong>on</strong>e of the communicati<strong>on</strong><br />

modules enables easy data<br />

collecti<strong>on</strong> <strong>an</strong>d tr<strong>an</strong>sfer.<br />

5/6. Strainer<br />

Stati<strong>on</strong>s c<strong>an</strong> be fitted <strong>with</strong> strainers:<br />

heating supply (primary) <strong>an</strong>d heating<br />

return (sec<strong>on</strong>dary), <strong>an</strong>d <strong>with</strong> a filter<br />

in the cold water input for the hot<br />

water c<strong>on</strong>troller.<br />

7. Heat insulati<strong>on</strong><br />

The Neopolen heat insulati<strong>on</strong><br />

complies <strong>with</strong> the requirements of<br />

energy c<strong>on</strong>servati<strong>on</strong> regulati<strong>on</strong>s.<br />

8. Room thermostat - together <strong>with</strong><br />

electro-thermal actuator <strong>with</strong><br />

z<strong>on</strong>e valve<br />

Installed in the flat stati<strong>on</strong>’s return<br />

side, enables hydr<strong>on</strong>ic bal<strong>an</strong>cing <strong>an</strong>d<br />

the central c<strong>on</strong>trol of room temperature,<br />

timer <strong>an</strong>d night set-back. This<br />

gives maximum heating comfort <strong>an</strong>d<br />

additi<strong>on</strong>al energy savings to end users.<br />

Room thermostat c<strong>an</strong> be m<strong>an</strong>ual<br />

or programmable.<br />

M<strong>an</strong>ually adjustable room thermostat<br />

type RMT-230 <strong>with</strong>:<br />

– adjustable temperature: 8-30 °C,<br />

– power: 230 V AC,<br />

– switching differential (<strong>on</strong>/off): 0.6 K<br />

is supplied as st<strong>an</strong>dard.<br />

25<br />

What is the EvoFlat <strong>system</strong> soluti<strong>on</strong><br />

For users <strong>with</strong> higher dem<strong>an</strong>ds for<br />

comfort it is possible to use programmable<br />

thermostats TP5001 <strong>with</strong> a<br />

weekly program (5/2) <strong>an</strong>d TP7000 <strong>with</strong><br />

a daily program (6 intervals), <strong>an</strong>d <strong>with</strong><br />

the possibility of lowering the night<br />

temperature.<br />

Piping <strong>an</strong>d c<strong>on</strong>necti<strong>on</strong>s<br />

All elements built into flat stati<strong>on</strong> are<br />

c<strong>on</strong>nected by pipes made of stainless<br />

steel. Extremely low roughness of pipe<br />

<strong>an</strong>d special way of bending ensures<br />

silent operati<strong>on</strong> <strong>an</strong>d small dimensi<strong>on</strong>s<br />

of the stati<strong>on</strong>s. C<strong>on</strong>necti<strong>on</strong> elements<br />

used are made from brass (c<strong>on</strong>necti<strong>on</strong><br />

fittings, elbows <strong>an</strong>d T-pieces). All elements<br />

in the flat stati<strong>on</strong>s are c<strong>on</strong>nected<br />

<strong>with</strong> detachable fittings to allow easy<br />

replacement of parts <strong>an</strong>d easy mainten<strong>an</strong>ce.<br />

Rated nominal pressure of flat<br />

stati<strong>on</strong>s is PN 10 (16) as st<strong>an</strong>dard.<br />

Opti<strong>on</strong>s<br />

All flat stati<strong>on</strong>s c<strong>an</strong> be equipped <strong>with</strong><br />

domestic hot water circulati<strong>on</strong> set <strong>on</strong><br />

request. It c<strong>on</strong>sists of the pump <strong>with</strong><br />

timer, thermostat or both <strong>an</strong>d the required<br />

c<strong>on</strong>necti<strong>on</strong> lines.