CYLINDER HEAD<br />

Compression Ratio: 11.5:1<br />

Compression Ratio ATLANTIS 100: 9.5:1<br />

PREDATOR LC / O2<br />

- The gaskets should be replaced every time the<br />

cylinder head is removed.- Check that the cylinder<br />

head is gas-tight. There should be no more<br />

than 0.05 mm gap.<br />

Cylinder head torque settings: 10 - 12 Nw x m.<br />

Cylinder head torque settings<br />

ATLANTIS 100: 18 - 20 Nw x m.<br />

PREDATOR LC<br />

Thermostat<br />

Starts to open at 55º ± 2 ºC<br />

Length of travel 3.5 mm 60º ± 2 ºC<br />

Thermoresistance<br />

For temperature gauges with needle<br />

Temperature º C Resistance ± 10 % Ω<br />

25 788<br />

80 98<br />

Thermocontact<br />

For models with electrical fan<br />

Make contact at 97 ± 3 ºC<br />

Break contact at 85 ± 3 ºC<br />

Cooling system<br />

Coolant antifreeze:<br />

AGIP CLOSED SYSTEM PLUS 30%<br />

Cooling system capacity Predator LC......825 c.c.<br />

Cooling system capacity Atlantis LC........400 c.c.<br />

Pressure in cooling system......................1.2 ± 1º<br />

Spark plugs<br />

PREDATOR O2 NGK B 8 HS / CHAMPION L 78 C<br />

ATLANTIS NGK B 8 HS / CHAMPION L 78 C<br />

PREDATOR L.C. NGK B 9 ES / CHAMPION N 2 C<br />

ATLANTIS L.C. NGK B 9 ES / CHAMPION N 2 C<br />

ATLANTIS 100 NGK B 9 ES / CHAMPION N 2 C<br />

PREDATOR L.C. (CAT) NGK B 8 ES / CHAMPION N 3 C<br />

59