CYLINDER HEAD<br />
Compression Ratio: 11.5:1<br />
Compression Ratio ATLANTIS 100: 9.5:1<br />
PREDATOR LC / O2<br />
- The gaskets should be replaced every time the<br />
cylinder head is removed.- Check that the cylinder<br />
head is gas-tight. There should be no more<br />
than 0.05 mm gap.<br />
Cylinder head torque settings: 10 - 12 Nw x m.<br />
Cylinder head torque settings<br />
ATLANTIS 100: 18 - 20 Nw x m.<br />
PREDATOR LC<br />
Thermostat<br />
Starts to open at 55º ± 2 ºC<br />
Length of travel 3.5 mm 60º ± 2 ºC<br />
Thermoresistance<br />
For temperature gauges with needle<br />
Temperature º C Resistance ± 10 % Ω<br />
25 788<br />
80 98<br />
Thermocontact<br />
For models with electrical fan<br />
Make contact at 97 ± 3 ºC<br />
Break contact at 85 ± 3 ºC<br />
Cooling system<br />
Coolant antifreeze:<br />
AGIP CLOSED SYSTEM PLUS 30%<br />
Cooling system capacity Predator LC......825 c.c.<br />
Cooling system capacity Atlantis LC........400 c.c.<br />
Pressure in cooling system......................1.2 ± 1º<br />
Spark plugs<br />
PREDATOR O2 NGK B 8 HS / CHAMPION L 78 C<br />
ATLANTIS NGK B 8 HS / CHAMPION L 78 C<br />
PREDATOR L.C. NGK B 9 ES / CHAMPION N 2 C<br />
ATLANTIS L.C. NGK B 9 ES / CHAMPION N 2 C<br />
ATLANTIS 100 NGK B 9 ES / CHAMPION N 2 C<br />
PREDATOR L.C. (CAT) NGK B 8 ES / CHAMPION N 3 C<br />
59