CHARGING SYSTEM:<br />
- It is necessary to use a charger with constant voltage<br />
and current.<br />
Standard charge: 0.3 Ah for 10 hours if the<br />
voltage is below 12.5 volts.<br />
- Carry out battery charging in accordance with the<br />
accompanying table.<br />
Standard values for determining the<br />
condition of the battery<br />
Voltage is 12.5 or higher Correct<br />
Voltage between 12.0 - 12.4 Insufficient charge<br />
(recharge battery)<br />
Voltage at 11.9 or less Unserviceable<br />
(replace battery)<br />
STARTER RELAY<br />
- Check the resistance between each of the terminals.<br />
- Resistance between 85 and 86 = 55 Ω ±15%.<br />
- In order to measure continuity between the contacts,<br />
connect poles 85 and 86 to the battery and<br />
pole 30 and 87 to the tester: the result of this test<br />
should be a reading of 0 ohms (closed circuit).<br />
When poles 85 and 86 are disconnected from the<br />
battery, the tester should read infinity, or open circuit.<br />
- If there is any variation from these readings, the<br />
relay should be replaced.<br />
WIRING DIAGRAM AND CONTROL OF THE FAN CIRCUIT<br />
64<br />
- +<br />
BATTERY<br />
FUSE 4 AMP<br />
Charging time<br />
IGNITION SWITCH<br />
R/BL RED/ BLACK + FROM IGNITION SWITCH<br />
WH WHITE + FROM FAN<br />
Voltage at the terminals (V)<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
0<br />
13,0<br />
12,5<br />
12,0<br />
Standard battery charging times<br />
11,5 12,0 12,5 13,0 V<br />
Voltage at the battery terminals<br />
Control diagram to determine<br />
battery state<br />
11,5<br />
0 25 50 75<br />
Battery Charge (%)<br />
30<br />
85 86<br />
87<br />
THERMOCONTACT<br />
4AMP<br />
R/BL<br />
FAN<br />
WH<br />
100<br />
Recharging necessary Battery Charged