17.08.2013 Views

Data Interfaces

Data Interfaces

Data Interfaces

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R/2 R/3 Communication (IBM)<br />

Connection setup from R/2<br />

Host Host (K50)<br />

(K50)<br />

R/2<br />

R/2<br />

ABAP/4 ABAP/4<br />

Dest LU TP<br />

T01 MP30 T01<br />

(hs5000)<br />

© SAP AG<br />

LU6.2<br />

hs5000<br />

SNA SNA subsystem<br />

subsystem<br />

Progr: Progr: gwhost<br />

gwhost<br />

SAP SAP gateway<br />

gateway<br />

TCP/IP (remote)<br />

shared memory (local)<br />

Table XCOM (K50) Side info from gwhost<br />

DEST = T01<br />

LU = hs5001<br />

TP = sapgw00<br />

GWHOST = hs5001<br />

GWSERV = sapgw00<br />

Protocol = I<br />

hs5001, sapgw00<br />

UNIX, UNIX, NT NT (T01)<br />

(T01)<br />

SAP SAP gateway<br />

gateway<br />

R/3<br />

R/3<br />

ABAP/4<br />

ABAP/4<br />

The switching program gwhost is started on the machine where the SNA software is installed. gwhost<br />

then looks for an entry in the side information table where the destination matches the TP specification in<br />

the R/2 table XCOM (the program started by the SNA subsystem does not have to be called gwhost - it<br />

can be copied beforehand or a symbolic link can be set up, e.g. ln -s gwhost T01). If you want to set up a<br />

connection from R/2 to several R/3 Systems, each R/3 System must be defined at the SNA services level<br />

on the one hand, and have its own intermediate program (e.g. T01, T02, ... ) on the other. There must of<br />

course also be an entry in the side information table for each R/3 System. The symbolic destination is<br />

identical with the name of the intermediate program (DEST=T02). To reach different destinations, e.g.<br />

different R/3 Systems, this means that the intermediate program must be declared to the SNA subsystem<br />

under different names.<br />

You should ensure that the side information file can be found and read by the switching program. To do<br />

this, you need to know the identity of the user who started the program. Of course, the authorizations of<br />

the side information file must be set so that the user can read them.<br />

The switching program is required for CPI-C and RFC connections.<br />

For an RFC connection, you need to make the appropriate entry in the table RFCD.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!