<strong>POWER</strong>-<strong>MASTER</strong> <strong>500</strong> 430581-004<br />
Standard Features<br />
The power source has the fol low ing stan dard<br />
fea tures.<br />
a. Short-Circuit Pro tec tion – The out put of the<br />
power source can be short cir cuited in any of the<br />
modes of op er a tion. This pro tec tion fea ture will<br />
in stantly limit the out put cur rent to a safe value, to<br />
as sure re li able op er a tion of the power source.<br />
b. Out put Over load Pro tec tion – The over load<br />
pro tec tion fea ture will limit the con tin u ous weld<br />
cur rent to the max i mum value listed in the spec i fi -<br />
ca tions for any of the modes of op er a tion. The<br />
ma chine will con tinue to op er ate but the cur rent<br />
will be lim ited to this max i mum value.<br />
c. Cooling Fan Con trol – The cool ing fans are<br />
de signed to op er ate only when re quired. They<br />
will come on when ever the out put contactor con -<br />
trol of the ma chine is on. The fans will come on for<br />
sev eral min utes when the ma chine is first turned<br />
on and will nor mally stay on for sev eral min utes<br />
af ter the out put contactor con trol has been<br />
switched off. The fans will turn off af ter sev eral<br />
min utes of in ac tiv ity, to min i mize the amount of<br />
Net weight: 154 LBS<br />
Fig ure 3-2 Power Source Di men sions<br />
dirt be ing drawn into the ma chine, as well as<br />
lengthen the life of the fans.<br />
d. Overtemperature Pro tec tion – If the ma -<br />
chine over heats be cause of blocked air flow, ex -<br />
ces sive am bi ent tem per a tures, failed fan, or<br />
other cause, the overtemperature pro tec tion will<br />
dis able the out put of the power source un til it has<br />
cooled down. If the overtemperature pro tec tion<br />
cir cuit op er ates, it will turn on the in di ca tor light<br />
on the front panel and the fans should con tinue to<br />
run un til the ma chine cools. The<br />
overtemperature cir cuit will re set it self au to mat i -<br />
cally once the ma chine has cooled.<br />
e. Multi-Voltage Op er a tion – The power source<br />
is de signed to op er ate from a wide range of in put<br />
line volt ages as given in the spec i fi ca tions. The<br />
ma chine can be re con fig ured for the dif fer ent line<br />
volt ages with a sim ple, rug ged volt age change -<br />
over panel ac ces si ble by re mov ing the left side<br />
panel of the ma chine. (See in stal la tion chap ter<br />
for de tailed in struc tions).<br />
3-3